Error messages (continued)

Monitor display

Description

Corrective action

VTR operation

 

 

 

 

 

If the take-up reel fails to take up the tape while the

 

 

E-52

tape is traveling in the state where the total amount of

Set the POWER switch

 

W-UP REEL

the tape has not yet been detected after the cassette

to OFF and then to ON

STOP

NOT ROTA

was inserted, this error number flashes on the

again.

 

 

display.

 

 

 

 

 

 

 

If there is an abnormally large discrepancy between

 

 

 

the amount of tape taken up by the take-up reel and

Set the POWER switch

 

E-53

the amount of tape supplied by the supply reel while

 

WINDUP ERROR

the tape is traveling after the total amount of the tape

to OFF and then to ON

STOP

 

begins to be detected, this error number flashes on

again.

 

 

the display.

 

 

 

 

 

 

E-55

If the tape has not been taken up during unloading,

Set the POWER switch to

STOP

UNLOAD ERROR

this error number flashes on the display.

OFF and then to ON again.

 

 

 

 

 

E-57

If the start or end processing operation is not

Set the POWER switch

STOP

S-FF/REW

completed, this error number flashes on the display.

to OFF and then to ON

TIMEOVER

again.

 

 

 

 

 

 

 

E-59

If the cylinder motor speed is abnormally low, this

Set the POWER switch

 

DRUM ROTA

to OFF and then to ON

STOP

TOO SLOW

error number flashes on the display.

again.

 

 

 

 

 

 

 

E-60

If the cylinder motor speed is abnormally high, this

Set the POWER switch

 

DRUM ROTA

to OFF and then to ON

STOP

TOO FAST

error number flashes on the display.

again.

 

 

 

 

 

 

 

E-61

If the capstan motor speed is abnormally low, the

Set the POWER switch

 

CAP ROTA

to OFF and then to ON

STOP

TOO SLOW

error number flashes on the display.

again.

 

 

 

 

 

 

 

E-64

If the supply reel motor speed is abnormally high, the

Set the POWER switch

 

S REEL ROTA

to OFF and then to ON

STOP

TOO FAST

error number flashes on the display.

again.

 

 

 

 

 

 

 

E-67

If the take-up reel motor speed is abnormally high,

Set the POWER switch

 

T REEL ROTA

to OFF and then to ON

STOP

TOO FAST

the error number flashes on the display.

again.

 

 

 

 

 

 

 

E-69

If excess torque being applied to the take-up reel

Set the POWER switch

 

T REEL

motor is detected, the error number flashes on the

to OFF and then to ON

STOP

TORQUE ERR

display.

again.

 

 

 

 

 

E-70

If excess torque being applied to the supply reel

Set the POWER switch

 

S REEL

motor is detected or an abnormal current flowing to

 

TORQUE ERR

the current detection resistor is detected, this error

to OFF and then to ON

STOP

 

number flashes on the display.

again.

 

 

 

 

 

 

 

 

E-71

If abnormal tension at the supply side is detected in

Set the POWER switch

 

CAP TENSION

the capstan mode, the error number flashes on the

to OFF and then to ON

STOP

ERROR

display.

again.

 

 

 

 

 

E-72

If abnormal tension at the supply side is detected in

Set the POWER switch

 

REEL TENSION

the reel mode, the error number flashes on the

to OFF and then to ON

STOP

ERROR

display.

again.

 

 

 

 

 

E-73

If the take-up reel motor has rotated in the reverse

Set the POWER switch

 

REEL DIR

to OFF and then to ON

STOP

UNMATCH

direction, this error number flashes on the display.

again.

 

 

 

 

 

 

 

E-74

If excess torque being applied to the cylinder motor is

Set the POWER switch

 

DRUM TORQUE

to OFF and then to ON

STOP

ERROR

detected, this error number flashes on the display.

again.

 

 

 

 

 

 

 

E-78

If a problem has been encountered in communication

Set the POWER switch

 

M-IF COMM

between the servo microcomputer and mechanism

to OFF and then to ON

STOP

ERROR

relay board, this error number flashes on the display.

again.

 

 

 

 

 

Note:

Consult your dealer if the error message is still displayed even after restarting the unit.

– 42 –