Parts and their functions (continued)
Front panel
POWER |
|
|
|
|
|
|
|
|
| EJECT |
ON |
|
|
|
|
|
|
|
|
|
|
OFF |
|
|
|
|
|
|
|
|
|
|
CONTROL | REC INHIBIT |
|
|
|
|
|
|
|
| |
LOCAL REMOTE | OFF | ON |
| Digital Video Cassette Recorder AJ- |
|
|
|
| ||
METER |
|
|
|
|
|
|
|
|
| PUSH |
FULL/FINE |
|
|
|
|
|
|
|
|
| SHTL/SLOW |
|
|
|
|
|
|
| SEARCH | PLAY | REC | |
|
|
|
|
|
|
|
|
| ||
MONITOR SEL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| REW | STOP | FF |
HEADPHONES | CH 1 | CH 2 | CH 3 | CH 4 | REC PB | INPUT SELECT | COUNTER RESET | TC | INT | TCG SUPER |
|
|
|
|
| VIDEO AUDIO | PRESET | MENU | ON | ||
|
|
|
|
|
|
|
| REGEN | ||
|
|
|
|
|
|
|
|
| PRESET | OFF |
|
|
|
|
|
|
|
|
| EXT | |
|
|
|
|
| UNITY | PF | PF1 PF2 | PF3 | DIAG |
|
SEARCH button
INPUT SELECT buttons
These buttons are used to switch the video and audio input signals. They can also be used to switch the input signals to the internal reference signal selected as the setup menu item No.600 (INT SG) setting.
VIDEO:
Each time the VIDEO button is pressed, the input video signal selection is switched in the order of [Y PB PR] →[CMPST] → [SDI] → [1394] → [SG].
•When SG has been selected, the signal is switched to the internal reference signal selected
as the setup menu item No.600 (INT SG) setting.
AUDIO:
Each time the AUDIO button is pressed, the input audio signal selection is switched in the order of [ANALOG] → [SDI] → [1394] → [SG].
Notes:
•It is possible to inhibit the input switch operations (video and audio) of the INPUT SELECT buttons using setup menu item No.112 (V IN SEL INH) and item No.113 (A IN SEL INH).
•The Y PB PR and CMPST settings for the VIDEO button as well as the ANALOG setting for the AUDIO button cannot be selected unless the optional board
•The SDI setting for the VIDEO and AUDIO buttons cannot be selected unless the optional board (AJ- YA94G) has been installed.
PF button
When this button is pressed, buttons to
function as the PF1, PF2 and PF3 buttons, respectively. When it is pressed again before another button is pressed, these modes are canceled.
When this button is pressed together with the MENU/DIAG button , the DIAG screen is displayed.
COUNTER/PF1 button
Each time this button is pressed, the counter display on the display panel changes by one step in the following sequence: CTL → TC → UB.
RESET/PF2 button
When this button is pressed in the CTL mode, the counter display is reset to [00:00:00:00].
When it is pressed in the TC/UB mode while holding
down the TC PRESET button , the generator is reset.
TC PRESET/PF3 button
This button is used to set the TC or UB values.
MENU/DIAG button
When this button is pressed, the setup menus are displayed on the TV monitor (but only when the VIDEO MON connector is used), and the setup menu numbers are displayed on the unit’s display panel.
When it is pressed again, the setup menu settings are exited, and the original status is restored.
When the button is pressed while holding down the PF
button , the VTR information is displayed. When it is pressed again, the original display is restored. The VTR information consists of the WARNING, HOURS METER, UMID and DIF STATUS 1, 2 information. The SEARCH button is used to switch the displays between these kinds of information.
Descriptions of the warnings are displayed on the WARNING screen. The deck’s serial number, power- on time, drum rotation time, tape travel time, number of loading times, number of power on/off times, etc. are displayed on the HOURS METER screen. The UMID (Unique Material Identifier) information is displayed on the UMID INFO screen. The IEEE 1394 digital interface information is displayed on the DIF STATUS 1, 2 screen.
TCG switch
REGEN:
The internal time code generator is synchronized with the time code which the time code reader has read from the tape.
The signal that is to be used for regeneration is selected using setup menu No. 503 (TCG REGEN).
PRESET:
The time code generator can be preset (see page 35) on the operation panel or by remote control.
EXT:
The external time code which is input from the time code input connector or video signal VITC, or IEEE1394 digital input signal is used. Which of the two is to be set is selected using setup menu No. 505 (EXT TC SEL).
SUPER switch
ON : The time code and other superimposed information are output to the VIDEO MON connector.
OFF : No superimposed information is output.
– 9 –