Picture monitor (PM) displays
Switching the display
Display the camera statuses, warnings, and other information on the picture monitor using the operation panel of the ROP..
Press the CHARA button of the ROP to display the desired information.. The camera statuses, warnings, and other information are cleared when the CHARA button of the ROP is held down..
CHARA button
ROP:
Transition of displays
When trouble is detected, warning information is automatically displayed on the picture monitor..
Even if status information or operation information is already displayed on the picture monitor when trouble is detected, priority is given to the display of the warning information..
The descending sequence of priority for the displays on the picture monitor is as follows: WARNING displays → AUTO displays → STATUS displays → REMOTE OPERATION menu displays → CCU menu displays → OPERATION displays → no display..
When the warning information with the highest priority disappears, the warning information with the next highest priority appears..
Sequence of | What is displayed on the | ROP connected | |||
|
| ||||
priority | screen | Yes | No | ||
|
|
| |||
|
|
|
|
| |
Higher | WARNING displays | Warnings are automatically displayed when | Warnings are automatically displayed when | ||
| trouble is detected.. | trouble is detected.. | |||
|
|
| |||
|
|
| |||
|
|
| The warning displays are cleared.. | The warning displays are cleared.. | |
|
|
| |||
|
|
| zzPress the CHARA button of the ROP | zzPress the SELECT dial on the unit | |
|
|
| The display switches to the status screen (IRIS | When the transition source screen is displayed: | |
|
|
| or status display).. | The display switches to the transition source | |
|
|
| zzHold down the CHARA button of the ROP | screen.. | |
|
|
| The warning displays are cleared.. | When the transition source screen is not | |
|
|
|
| displayed: | |
|
|
|
| The warning displays are cleared.. | |
|
|
|
|
| |
|
| AUTO displays | Automatically displayed | Automatically displayed | |
|
|
|
|
| |
|
| STATUS displays | Perform display operations using the CHARA |
| |
|
|
| button of the ROP.. |
| |
|
|
| zzPress the CHARA button of the ROP |
| |
|
|
| No display → (WARNING) → IRIS → status |
| |
|
|
| displays → Status1 → Status2 → Status3 → |
| |
|
|
| Status4 → Status1 .... . |
| |
|
|
| zzHold down the CHARA button of the ROP |
| |
|
|
| The status displays end.. |
| |
|
|
|
|
| |
|
| REMOTE OPERATION menu | Display by pressing the CHARA button of the |
| |
|
| displays | ROP.. |
| |
|
| zzWhen a menu of the CCU | zzOperations using the SELECT dial of the ROP |
| |
|
| (this unit) is displayed while |
|
| |
|
| the REMOTE OPERATION |
|
| |
|
| menu is displayed, the |
|
| |
|
| REMOTE OPERATION menu |
|
| |
|
| disappears.. |
|
| |
|
| CCU menu displays | Display by pressing the MENU button on the unit.. | Display by pressing the MENU button on the unit.. | |
|
| zzWhen the REMOTE | zzOperations using the SELECT dial on the unit | zzOperations using the SELECT dial on the unit | |
|
| OPERATION menu is |
|
| |
|
| displayed while a menu of the |
|
| |
|
| CCU (this unit) is displayed, |
|
| |
|
| the menu of the CCU (this |
|
| |
|
| unit) disappears.. |
|
| |
|
|
|
|
| |
|
| OPERATION displays | Automatically displayed | Automatically displayed | |
Lower |
|
|
| ||
No display | |||||
|
| ||||
|
|
|
|
|
3