Picture monitor (PM) displays (Continued)

zzOperation displays (manual)

The operation displays appear at the bottom of the screen for 4 seconds when any of the following operations have been performed with the operation panel of the ROP..

zz“MASTER GAIN” is changed zz“SHUTTER” is changed zz“LENS EXT” is changed zz“FILTER” is changed zz“SCENE FILE” is changed zz“REF LOAD” is changed

The display time can be changed from “MAINTENANCE” menu → “PM

OPERATION STATUS” → “STATUS DISP TIME”..

FILTER FIL1

Item

Display

Remarks

 

range

 

MASTER GAIN

Setting

The master gain value is displayed

 

values on

here..

 

camera

(in 3 dB increments)

 

 

zzFor the setting values, refer to the

 

 

Operating Instructions for the camera..

 

 

 

SHUTTER

Setting

The speed of the electronic shutter is

 

values on

displayed here..

 

camera

zzFor the setting values, refer to the

 

 

Operating Instructions for the camera..

 

 

 

LENS EXT

1..0

The magnification of the lens extender

 

2..0

is displayed here..

 

 

zzWhen the magnification of the

 

 

lens extender is set to 2×, “2..0” is

 

 

displayed..

 

 

Otherwise, “1..0” is displayed..

 

 

 

FILTER

4 characters

The name of the ND filter is displayed

 

 

here..

 

 

 

SCENE FILE

SCENE1

This indicates the scene file name..

 

 

 

SCENE4

 

 

OFF

 

 

 

 

REF LOAD

FACTORY

This indicates the reference file that was

 

USER1

loaded using the SCENE command..

 

USER2

 

 

USER3

 

 

 

 

zzOperation displays (AUTO)

If the AWB function, ABB function, or AUTO SETUP function has been activated when a menu is not displayed on the picture monitor, information on the operation performed appears at the bottom of the screen..

When the AUTO SETUP operations are displayed, they will remain displayed until the operations are completed..

The display is cleared 4 seconds after the operations are completed.. If the operations cannot be completed, they will remain displayed until the NG (error) items of the AUTO function are released..

The display time can be changed from “MAINTENANCE” menu → “PM

OPERATION STATUS” → “STATUS DISP TIME”..

AUTO SETUP: ACTIVE

GAMMA OPERATION

 

Display description:

 

Item

Appears on two lines at the bottom of the screen..

 

 

 

 

Top line: status

 

 

 

 

Bottom line: Detailed information

 

 

 

 

 

ABB START

ABB: ACTIVE

 

 

 

 

 

 

 

 

 

(None)

 

 

 

 

 

 

 

 

AWB START

AWB: ACTIVE

 

 

 

 

 

 

 

 

 

(None)

 

 

 

 

 

 

 

 

AUTO OK

ABB: OK

AWB: OK

AUTO SETUP: OK

(Common to

 

 

 

 

(None)

 

 

 

ABB, AWB, and

 

 

 

 

 

 

 

AUTO SETUP)

 

 

 

 

 

 

 

 

AUTO NG1*1

ABB: NG

 

AWB: NG

(Only for ABB

 

 

 

 

Detailed information of the NG (error) message is

and AWB)

displayed here*1..

 

 

 

 

 

 

AUTO SETUP

AUTO SETUP: ACTIVE

 

START*2

 

 

 

 

Detailed information is displayed here*2..

 

 

 

 

AUTO NG2*3

AUTO SETUP: NG

 

(Only for AUTO

 

 

 

 

Detailed information of the NG (error) message is

SETUP)

displayed here*3..

 

 

 

 

 

 

 

AUTO BREAK

ABB: BREAK

AWB: BREAK

AUTO SETUP: BREAK

(Common to

 

 

 

 

(None)

 

 

 

ABB, AWB and

 

 

 

 

 

 

 

AUTO SETUP)

 

 

 

 

 

 

 

AUTO READY

AUTO SETUP: READY

 

(Only for AUTO

 

 

 

 

(None)

 

 

 

SETUP)

 

 

 

 

 

 

 

 

 

 

 

 

7