To control a remote camera connected via an IP connection from the unit, you need to set the network settings of the unit.
Note
zzCorrect operation is not possible if the same IP address already exists in the same network.
Set IP addresses that are not duplicates of any existing IP addresses.
Setting the IP address of the unit
1.Open RP SETUP menu [25] and turn the F1 dial to display the “7. IP ADDRESS” item.
7.IP ADDRESS
192 168.000.009
zzThis is set to “192.168.000.009” by default.
2.Use the F2 dial to set the IP address of the unit to one that is not a duplicate of that of another device.
Enter this in four blocks of numerals.
Enter all of the blocks and then press the F2 dial to confirm the IP address.
zzWhen the IP address is a duplicate of that of a remote camera or switcher connection destination, the following message appears and the IP address is not set.
7.IP ADDRESS IP Duplicate!
zzWhen you enter a value that cannot be set, the following message appears and the IP address is not set.
Refer to the “Settable addresses” (page 28) memo.
Unavailable
network setting
Notes
zzIn order for the setting to take effect, the unit must be restarted. Turn off the unit’s power, and then turn it back on.
zzConsult the network administrator before setting the IP address.
Setting the subnet mask
1.Open RP SETUP menu [25] and turn the F1 dial to display the “8. SUBNETMASK” item.
8.SUBNETMASK
255 255.255.000
zzThis is set to “255.255.255.000” by default.
2.Use the F2 dial to set the subnet mask of the unit.
Enter this in four blocks of numerals.
Enter all of the blocks and then press the F2 dial to confirm the subnet mask.
zzWhen you enter a value that cannot be set, the following message appears and the subnet mask is not set. Refer to the “Settable addresses” (page 28) memo.
Unavailable
network setting
Note
zzIn order for the setting to take effect, the unit must be restarted. Turn off the unit’s power, and then turn it back on.
Setting the default gateway
1.Open RP SETUP menu [25] and turn the F1 dial to display the “9. GATEWAY” item.
9.GATEWAY
192 168.000.001
zzThis is set to “192.168.000.001” by default.
2.Use the F2 dial to set the default gateway of the unit.
Enter this in four blocks of numerals.
Enter all of the blocks and then press the F2 dial to confirm the default gateway.
Note
zzIn order for the setting to take effect, the unit must be restarted. Turn off the unit’s power, and then turn it back on.
27