Settings for connecting with the remote cameras and switcher (continued)

192.168.000.010

192.168.000.011

192.168.000.010

 

192.168.000.010

192.168.000.010

Remote

192.168.000.012

 

 

 

camera B

Remote

Remote

 

 

camera C

camera A

 

 

CAM2

CAM3

 

CAM1

 

 

 

 

 

Switcher

Unit

192.168.000.008

 

192.168.000.009

192.168.000.008

zzThe subnet mask, default gateway, and port number settings are set the same as those for the unit.

zzFor the camera numbers for which “auto IP setting” is executed, the connection type becomes “Network” and the camera numbers are excluded from the setting targets the next time “auto IP setting” is executed.

However, camera numbers for which the connection destination IP address was changed manually or connection type was changed to “NoAsign” or “Serial” and then returned to “Network” after “auto IP setting” was executed become target for “auto IP setting” again.

<Operating procedure> Note

zzBefore configuring the settings, check that the connection types of the remote cameras are “NoAsign”.

Connection type settings

CTRL TYPE menu [36] → “1. CAM1” to “100. CAM100” items

1.Connect the remote cameras, switcher and unit to the network within the same subnet.

2.Open AUTO IP menu [37], turn the F2 dial to display “RENEW IP ADR” and press the F2 dial.

1.AUTO SET

RENEW IP ADR

Both the number of devices (all remote cameras and the switcher) currently being managed by the unit and the number of new devices detected are displayed on the LCD panel.

C:003/003 S:1/1

NO

C:003/003

Number of devices currently managed by the unit

+number of new devices detected Number of new devices detected

C:Remote camera, S: Switcher

3.Turn the F2 dial to select “Yes”, and then press the F2 dial.

“Auto IP setting” starts.

During “auto IP setting”, the progress is indicated by the number of

” which are reduced one by one.

1.AUTO SET

   

When all the operations have been completed successfully, the following message appears.

1.AUTO SET

COMPLETE

The remote cameras and the switcher are automatically rebooted, and they restart with the new IP addresses that were set.

The remote cameras can now be operated from the unit.

The function for linking the switcher with the unit can now be used.

zzWhen setting the IP addresses failed, the following message appears.

1.AUTO SET

SET UP ERR!

The cause of the problem is likely to be a network malfunction. Check the connection status of the hub and LAN cables, and then retry the “auto IP setting” operation.

31