HOW TO USE EXTERNAL

CONTROL

ABOUT EXTERNAL CONTROL

The Multi-Format Monitor has two external control terminals.

One is the MAKE/TRIGGER terminal, which allows the monitor to be controlled by the MAKE(make contact) or TRG. (trigger contact) method selected in the function setting.

MAKE (make contact system): Controls the function by stable disconnection (terminal open) or short-circuiting (short with GND of 15th terminal) of the controlled terminal.

TRG. (trigger system) : Controls the function by instantaneously (one second) short-circuiting (short with GND of 15th terminal) the controlled terminal.

*MAKE or TRIGGER are selected from REMOTE SYSTEM in the setup menu.

*The 14th terminal (REMOTE ENABLE) is always controlled by the make contact system regardless of the REMOTE SYSTEM

setting.

The other terminal used for remote control is the RS-232C terminal. This allows the monitor to be controlled by a PC via serial communication.

NOTE: Control priority is in the following order; 1 MAKE/TRIGGER terminal > 2RS-232C terminal > 3 front panel buttons. When trigger contact is on, the front panel buttons can be operated.

 HOW TO USE THE MAKE/TRIGGER TERMINAL 10 9

8

7 6

Connections

 

 

 

5 4 3 2 1

 

 

 

 

 

 

Connect (short-circuit) the 15th terminal (GND) to each of the 1st through 14th terminals in the 3-line

 

 

15-pin D-sub connector. The functions of each terminal are listed below.

 

 

 

The Names and Functions of Terminals

 

15 14 13 12 11

 

 

 

 

 

 

No.

Names

Functions

Operations (OFF p[ ON)

 

*1

1

TALLY

Puts on the tally lamp.

Put off

Put on

 

 

 

 

 

 

 

 

 

2

INPUT A

Changes the input to INPUT A

Not change

Change

 

 

 

 

 

 

 

 

 

3

INPUT B

Changes the input to INPUT B

Not change

Change

 

 

4

INPUT C

Changes the input to INPUT C

Not change

Change

 

 

 

 

 

 

 

 

 

5

INPUT D

Changes the input to INPUT D

Not change

Change

 

 

6

INPUT E

Changes the input to INPUT E

Not change

Change

 

 

 

 

 

 

 

 

 

7

INPUT F

Changes the input to INPUT F

Not change

Change

 

 

 

 

 

 

 

 

 

8

COLOR OFF

Changes the picture black-and-white.

Not change

Change

 

 

9

AREA MARKER

Displays the area marker.

Not display

Display

 

 

 

 

 

 

 

 

 

10

ASPECT

Changes the screen ratio to 16:9

4:3

16:9

 

 

11

TALLY SELECT

Switch the tally lamp color.

GREEN

RED

 

 

 

 

 

 

 

 

12

MARKER

Selects the type of the area marker

Selection in the main unit

Selection in the remote

*2

 

 

 

 

control

 

 

13

STATUS

Displays the monitor’s status

Display

 

 

*3

 

 

 

 

 

 

 

14

REMOTE ENABLE

Makes the external control form the

Invalid

Valid

 

*4

 

 

MAKE terminal valid or invalid

 

 

 

 

15

GND

Used as a ground terminal

 

 

 

 

 

 

 

 

 

*1 : OFF stands for disconnection, and ON stands for short-circuit.

When trigger contact is on, the setting switches between ON and OFF every time the terminal is short-circuited. (Only TALLY is controlled by being OFF(disconnection) and ON(short-circuit).)

*2 : Selects the area marker size from AREA MARKER (setting on the main unit) or AREA MARKER-R (setting on the remote control) setting.

*3 : The STATUS function is activated when the connection to the STATUS terminal is changed (ON to OFF, or OFF to ON). The monitor’s status is displayed for 3 seconds.

*4 : Setting REMOTE ENABLE to ON enables remote control. (same for both MAKE/TRIGGER methods.)

Operation

1.Set REMOTE ENABLE to ON.

2.Short-circuit or disconnect the desired terminal. (When trigger contact is on, duration of short-circuit is approx. 1 second.)

Changing the Signal Input

1.Set REMOTE ENABLE to ON.

2.Short-circuit the desired INPUT terminal. (When trigger contact is on, duration of short-circuit is approx. 1 second.)

3.Disconnect the INPUT terminal selected above. The signal input is actually changed after the disconnection has been completed.

NOTES: • When more than two terminals are selected (short-circuited) from INPUT A through INPUT F, the signal input is not changed.

To control INPUT A through INPUT F, we recommend using the interlock switch, which turns off a switch when another switch is turned on.

When trigger contact is on, and if several terminals are short-circuited simultaneously, proper control cannot be done. It is always necessary to short-circuit one terminal for one operation. Also, use of the Tact Switch is recommended.