List of Error Codes

When turning on the computer, if one of the following error codes or messages is displayed, follow the instructions shown below. If the problem persists, or if the error code or message displayed is not shown here, contact Panasonic Technical Support. ( page 42)

Error Code/Message

0211: Keyboard error

0251: System CMOS checksum bad - Default configuration used

0271: Check date and time set- tings

0280: Previous boot incomplete - Default configuration used

0613: Serial Port*1 configura- tion changed

0614: Serial Port*1 config. error - device disabled

*1 The port name, such as A or B, is displayed, indicating the con- flicting ports.

Press <F2> to Setup

Operating System not found

Extended RAM Module Failed

Action

If an external keyboard or a mouse is connected, disconnect these devices.

An error has occurred in the memory that stores the Setup Utility settings. This error occurs when the memory content is changed through some inadvertent operation by a program or other function.

Run the Setup Utility and load the default values, then change the settings to the appro- priate values as needed.

If the problem persists, the internal clock battery may need to be replaced. Contact Pana- sonic Technical Support.

The date and time setting are incorrect.

Run the Setup Utility and set the date and time correctly.

If the problem persists, the internal clock battery may need to be replaced. Contact Pana- sonic Technical Support.

Startup has failed repeatedly, so the Setup Utility settings have been returned to their default values, and the computer has been booted.

Run the Setup Utility and load the default values, then change the settings to the appropri- ate values as needed.

I/O address and IRQ settings are in conflict.

Run the Setup Utility and change the settings in [Advanced] menu so there is no port conflicts.

Write down the error details and press F2 to run the Setup Utility. Confirm the settings, and change the settings to the appropriate values as needed.

The OS is not properly installed on the floppy disk or the hard disk that you are trying to boot from.

If the computer cannot be booted from the floppy disk, check the floppy disk drive to ensure that the disk is in fact bootable, and use another bootable disk if not.

If the computer cannot be booted from the hard disk, confirm whether the hard disk is properly recognized in [Information] menu of the Setup Utility.

If the hard disk is recognized, perform the reinstallation procedure.

If not, contact Panasonic Technical Support.

If a device is connected to the USB port, disconnect the device, or run the Setup Utility and set [Legacy USB Support] in [Advanced] menu to [Disable].

If the extended RAM module has not been inserted properly, or if an extended RAM module other than one matching the specifications has been inserted, a beep will sound and the message “Extended RAM Module Failed” will be displayed when turning the power on. In this case, turn the power off, confirm that the extended RAM module meets the specifications, and reinsert it.

To run the Setup Utility

1Restart the computer.

2 Press F2 while [Panasonic] boot screen is displayed soon after the computer begins the startup procedure.

24

Page 24
Image 24