MODEL

INDOOR

 

CS-CE12JKE

 

 

 

 

OUTDOOR

 

CU-CE12JKE

 

 

 

 

 

 

 

 

 

 

 

 

Dry Bulb

 

Wet Bulb

 

 

 

 

 

 

 

Cooling

Maximum

32

 

23

 

 

 

 

 

Indoor Operation Range

Minimum

16

 

11

 

 

 

 

 

 

 

Heating

Maximum

30

 

 

 

 

 

 

 

 

 

Minimum

16

 

 

 

 

 

 

 

 

 

 

 

Cooling

Maximum

43

 

26

 

 

 

 

 

Outdoor Operation Range

Minimum

16

 

11

 

 

 

 

 

 

 

Heating

Maximum

24

 

18

 

 

 

 

 

 

 

 

Minimum

-15

 

-6

 

 

 

 

 

 

 

 

 

1.Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)

2.Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)

3.Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C

4.Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C

5.Specifications are subjected to change without prior notice for further improvement.