Panasonic CU-3KE19NBU Special Remarks, Heating, Clicking Sound, Remote Controller, ‘‘Dry’’

Models: CS-MKE12NKU CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU CS-MKE7NKU CS-MKE9NKU

1 56
Download 56 pages 332 b
Page 46
Image 46
Manual background

 

 

 

SPECIAL REMARKS

 

 

 

 

 

‘‘DRY’’ (

) Operation

 

 

 

 

 

How it works?

• Once the room temperature reaches the level that was set, the unit’s operation

 

 

 

frequency is changed automatically.

 

 

 

• During DRY operation, the fan speed automatically runs at lower speed for

 

 

 

providing a comfortable breeze.

 

 

 

• ‘‘DRY’’ operation is not possible if the indoor temperature is 59 °F or less.

 

 

 

Heating (

) Operation

 

 

 

 

 

Heating performance

• Because this air conditioner heats a room by drawing in the heat of the

 

 

 

outside air (heat pump system), the heating efficiency will fall off when the

 

 

 

outdoor temperature is very low. If sufficient heat cannot be obtained with this

 

 

 

air conditioner, use another heating appliance together with it.

 

 

Defrosting

• When the outdoor temperature is low, frost or ice may form on the heat

 

 

 

exchanger coil, reducing heating performance. When this happens, a

 

 

 

microcomputer defrosting system operates. At the same time, the fan on the

 

 

 

indoor unit stops and the OPERATION lamp lights red and orange alternately

 

 

 

until defrosting is completed. Heating operation restarts after several minutes.

 

 

 

(This interval will vary slightly depending upon the outdoor temperature and

 

 

 

the way in which frost forms.)

 

Cold draft prevention

• For several minutes after the start of heating operation, the indoor fan runs at

 

 

 

a lower speed until the indoor heat exchanger coil has warmed up sufficiently.

 

 

 

However, the fan may remain stopped when the room temperature is low. This

 

 

 

is because the COLD DRAFT PREVENTION SYSTEM is in operating.

Power failure during operation

Clicking Sound

In the event of power failure, the unit will stop. When the power is resumed, the unit will restart automatically within 15 minutes by the remote controller.

Clicking sound is heard from the air conditioner

Remote Controller

In heating or cooling operation, any plastic parts may expand or shrink due to a sudden temperature change. In this event, a clicking sound may occur. This is normal, and the sound will soon disappear.

The remote controller sends the setting condition to the air conditioner regularly at five minute intervals.

17

Page 46
Image 46
Panasonic CU-3KE19NBU, CS-MKE9NKU, CS-MKE7NKU appendix Special Remarks, Heating, Clicking Sound, Remote Controller, ‘‘Dry’’