REMOTE CONTROLLER (CONTINUED)

 

 

 

MODE selector button

Use this button to select AUTO, HEAT, DRY or COOL mode.

(AUTO)

: The air conditioner calculates the difference between the thermostat

 

 

setting and room temperature, and automatically selects ‘‘COOL’’ or

 

 

‘‘HEAT’’ mode as appropriate.

 

(HEAT)

: The air conditioner makes the room warmer.

 

(DRY)

: The air conditioner reduces the humidity in the room.

(COOL)

: The air conditioner makes the room cooler.

 

 

When multiple indoor units are used and units in other rooms are already operating, they

 

NOTE

 

 

will be set to the same mode of operation as the operating indoor units.

 

 

 

 

 

FAN SPEED selector button

: The air conditioner automatically decides the fan speeds.

 

 

: High fan speed

 

 

: Medium fan speed

 

 

: Low fan speed

NIGHT SETBACK button For details, see “4. Night Setback Mode”. When you press this button in the

HEAT, DRY or COOL mode, the mark appears in the display, and the remote controller will automatically adjust the set temperature to save energy.

FLAP button Press this button either to select the setting of the airflow direction to the auto.

 

 

flap in each mode or one of the six possible positions manually or to select the

 

 

sweep function which moves the flap up and down automatically.

 

 

: Auto flap setting: If selected in a heating operation, the flap is set to

 

 

position (3) in the following chart. If selected in a cooling or dry operation,

 

 

the flap is set at position (7) in the following chart.

 

 

: The airflow direction can be set manually. (six positions)

 

 

: The flap moves up and down automatically.

 

 

When you press the FLAP button, the air flow direction will be changed one by

 

NOTE

 

 

one as follows.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWEEP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH POWER button

: If this button is pressed during HEAT, DRY or COOL operation, the unit

 

 

operates at maximum output for 30 minutes, regardless of the desired

 

 

temperature.

 

 

The fan speed is 1 step above “High”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON TIME/OFF TIME setting No display: The timer does not operate.

buttons

: The air conditioner starts at the set time.

 

 

: The air conditioner stops at the set time.

 

 

 

 

: The air conditioner stops and starts, or starts and stops, at the

 

 

 

 

set times every day. For details, see “SETTING THE TIMER”.

SENSOR button When you press this button (use a small-tipped object such as a ballpoint pen),

the mark will appear at the display. And the room temperature is detected by the sensor which is built into the indoor unit and the air conditioner is controlled accordingly.

NOTE If the remote controller is located near a heat source, such as a space heater or in direct sunlight, press the SENSOR button to switch to the sensor on the indoor unit.

NOTE

The indoor fan runs continuously when the system is in normal operation. It does not turn off when the desired room temperature is reached. If Night Set Back mode is selected, the fan will turn off intermittently during cooling operation in order to control air flow.

9

Page 38
Image 38
Panasonic CU-4KE31NBU, CS-MKE9NKU, CS-MKE7NKU, CU-4KE24NBU, CU-3KE19NBU, CS-MKE12NKU appendix Remote Controller

CS-MKE12NKU, CU-3KE19NBU, CU-4KE24NBU, CU-4KE31NBU, CS-MKE7NKU specifications

The Panasonic CS-MKE series comprises a range of advanced air conditioning units designed to provide efficient cooling and heating solutions for both residential and commercial spaces. The models in this series include the CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, each tailored to meet various needs while ensuring energy efficiency and user comfort.

One of the standout features of the CS-MKE series is its inverter technology. This innovative approach allows the air conditioner to adjust its compressor speed in accordance with the set temperature, leading to reduced energy consumption and lower utility bills. The inverter system operates smoothly, maintaining a consistent temperature without the bothersome on-off cycling typical of traditional units.

Moreover, the models in the CS-MKE range are equipped with the Plasma Quad Plus air purification technology. This feature effectively eliminates harmful particles and odors from the air, ensuring that the indoor environment is not only comfortable but also healthy. The air conditioning units can filter out dust, pollen, and various allergens, making them ideal for allergy sufferers or those with respiratory issues.

In terms of cooling and heating capacity, the CS-MKE series provides a versatile range. From the compact yet efficient CS-MKE7NKU, suitable for smaller rooms, to the robust CS-MKE24NKU designed for larger spaces, users can find an option that best suits their needs. Each model comes with adjustable airflow settings, allowing occupants to direct cool or warm air to where it's needed most, enhancing comfort levels.

The aesthetic design of the CS-MKE units is another appealing aspect. With their sleek and modern exterior, these air conditioners seamlessly blend into a variety of interior styles. Their ultra-quiet operation further enhances the user experience, making them suitable for bedrooms, offices, or any environment where noise reduction is a priority.

User-friendliness is a key characteristic of the CS-MKE series, boasting remote control features and programmable timers that allow users to set cooling or heating schedules, ensuring comfort upon arrival home while maximizing efficiency throughout the day.

Overall, the Panasonic CS-MKE series air conditioners, including models CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, offer a blend of advanced technology, energy efficiency, and design sophistication, making them a commendable choice for any space.