OPERATION

5

CONDITIONERPRODUCT SPECIFICATIONS ECONOMY OPERATION

Manual backgroundManual background CHECK TIMER SETTING DURING OFF TIMER

OPERATION

 

°F

To reduce power consumption:

ECONOMY

 

 

 

hr

Press ECONOMY.

ECONOMY

 

To cancel this operation, press once

 

 

 

 

more.

ECONOMY

Recommended for electricity cost saving. When economy button is pressed, target temperature is shifted up 1°F, this will reduce operating time of the compressor and therefore reduce power consumption. It may, however, take a little longer for the compressor to cycle on and thereby increase the room temperature slightly. Economy mode will override your current

°F

TIMER

hr

°F

hr

TIMER

Press the TIMER button to check the remaining programmed timer setting. The figure will be displayed for 10 seconds then will automatically switch back to temperature setting.

NOTE

The timer figure will change according to the time remaining (if you set it to turn off 3 hours from now, the timer will show “2” at an hour later).

CONDITIONER

set fan speed to “LOW”. However, the display will still show the current set fan speed. Compressor stops when the room temperature reaches the target temperature. It turns on again when the room temperature rises. When power failure occurs, the economy setting is canceled. Once power is resumed, reset the economy setting.

Manual backgroundManual background CANCEL TIMER SETTING DURING OFF TIMER

SET

°F

Press the SET/CANCEL button to

SET/

hr

cancel the timer setting. The SET/

CANCEL

 

 

 

SET/

CANCEL indicator light will turn off.

 

However the temperature remains

 

CANCEL

 

 

displayed.

AIR

6

PRODUCT SPECIFICATIONS

Manual backgroundManual background SETTING THE OFF TIMER

 

 

 

 

 

°F When the air conditioner in operation:

 

 

TIMER

 

 

 

 

 

 

 

 

hr Press the TIMER button.

 

 

 

 

 

 

 

 

The SET/CANCEL indicator light will

 

 

 

 

 

 

 

 

TEMP/TIMER

°F

blink awaiting for setting.

 

 

 

 

 

 

 

hr Press the TEMP/TIMER or button

 

 

SET

 

until the preferred hour of operation is

 

 

 

reached.

 

 

 

SET/

°F

 

 

 

 

 

 

 

 

 

 

 

CANCEL

 

 

hr

Press the SET/CANCEL button to

 

 

 

 

 

 

 

 

 

 

 

 

 

complete the setting. At this time, the

 

 

 

 

 

 

 

SET/CANCEL indicator light is steady

 

 

 

 

 

 

 

instead of blinking.

 

 

 

 

 

 

 

 

NOTE

 

 

 

 

TIMER

 

The hour reading will change back to the

 

 

 

 

 

 

 

set temperature reading after 10

 

 

 

TEMP/TIMER

 

seconds. (You can also revert to

 

 

 

 

 

 

 

temperature setting immediately by

 

 

 

 

 

 

 

 

 

 

SET/

 

pressing the TEMP/TIMER or

 

 

CANCEL

 

buttons again.)

 

 

 

 

 

 

 

 

 

 

Model

 

 

 

CW-XC122VU

 

 

 

COOLING CAPACITY

 

Btu/h

11,500

ELECTRICAL RATING

Phase

 

Single

 

 

 

 

 

 

Frequency

(Hz)

60

 

 

 

 

 

 

Voltage

(V)

115

 

 

 

 

 

 

Current

(Amps)

10.1

 

 

 

 

 

 

Input

(W)

1150

 

 

 

 

 

 

 

 

 

EER

 

 

(Btu/W.h)

10.0

MOISTURE REMOVAL

 

(Pints/h)

3.0

ROOM AIR CIRCULATION

(Cf/min)

330

DIMENSIONS

 

Height

cm (inches)

37.5 (14-25/32˝)

 

 

 

 

 

 

Width

cm (inches)

56 (22-1/16˝)

 

 

 

 

 

 

Depth

cm (inches)

60.6 (23-27/32˝)

NET WEIGHT

 

 

kg (lb)

35 (77)

GROSS WEIGHT

 

 

kg (lb)

39 (86)

NOISE LEVEL

 

Indoor (Hi/Lo)

dB (A)

51/47

 

 

 

 

 

 

Outdoor (Hi/Lo)

dB (A)

58/55

 

 

 

 

 

 

 

 

 