CONNECTIONS

Cautions :

1.Keep the DC POWER ON/OFF switch in the OFF posi- tion until all connections have been properly made.

2.Connect the camera head and camera control unit.

Internal Sync Operation

1.Connect the camera cable between the camera head and the camera control unit.

2.Connect the coaxial cable with BNC connectors between the video output connector of the camera control unit and the video monitor or VCR.

 

Video

VCR or

 

Monitor

Video Monitor

 

75

VIDEO

75

VIDEO

 

Hi-Z

Hi-Z

Coaxial

IN

OUT

IN

OUT

Cable

 

 

 

 

CCU

VBS/HD

VD

75

S-VIDEO

DC 12V IN

ON

OUT

RS-232C

 

 

OFF

 

1 VIDEO 2

 

 

 

 

RGB/SYNC

3.Connect the power cable between the DC 12 V input terminals and the 12 V DC power supply unit (obtained locally).

The maximum cable length between camera control unit and power supply unit is calculated as follows:

11.5V DC < VA - (R x 0.42 x L) < 16 V DC

L : Cable length (meter)

R : Resistance of copper wire (/meter)

VA : DC output voltage of power supply unit

L standard = VA - 12 / 0.42 x R (meter)

L minimum = VA - 16 / 0.42 x R (meter)

L maximum = VA - 11.5 / 0.42 x R (meter)

Cautions :

1.Connect to 12 V DC (11.5 V - 16 V) class 2 power supply only.

2.To prevent fire or electric shock hazard, use a UL listed wire VW-1, Style 1007 cable for 12 V DC input terminals.

Gen-lock Operation

1.Connect the camera cable between the camera head and the camera control unit.

2.Connect the coaxial cable with BNC connectors between the video output connector of the camera control unit and the video input connector of Special Effects Generator (SEG), and between the VBS/HD input connector of the camera control unit.

CCU

VBS/HD

VD

75

S-VIDEO

DC 12V IN

ON

OUT

RS-232C

 

 

OFF

 

1 VIDEO 2

 

 

 

 

RGB/SYNC

 

VBS/HD In

 

VIDEO Out

 

 

 

 

 

 

 

75set to ON

 

 

 

 

CCU

VBS/HD

VD

75

S-VIDEO

DC 12V IN

ON

OUT

RS-232C

 

 

OFF

 

1 VIDEO 2

 

 

 

 

RGB/SYNC

 

VBS/HD In

VIDEO Out

 

 

 

 

75set to ON

Black Burst VIDEO In

Out

Special Effects Generator

(SEG)

3.Connect the power cable between the DC 12 V input terminals and the 12V DC power supply unit (obtained locally).

Cautions :

1.Connect to 12 V DC (11.5 V - 16 V) class 2 power supply only.

2.To prevent fire or electric shock hazard, use a UL listed wire VW-1, Style 1007 cable for 12 V DC input terminals.

9

Page 9
Image 9
Panasonic GP-US532HA, GP-US522HA operating instructions Connections, Internal Sync Operation