Serial Repeater ID programming continued.
Ensure that the repeater is switched OFF. (both LED’s are OFF)
Power ON the repeater.
Assign the repeater to a base by following either the manual or automatic
registration process.
Bring the repeater into close range of the repeater on the parent level (i.e. when
assigning a repeater to chain-level 3, the repeater must be brought into close range
with the repeater already set to chain-level 2.).
Press the switch the corresponding number
of times to set the chain-level.
(i.e. 3 times = chain-level 3 etc.).
The red LED flashes a number of times
corresponding to the chain level.
NB: Pressing the switch 4 or more times
corresponds to chain-level 1.
After two minutes from power ON, the new chain-level and Radio Fixed Part Identity
(R.F.P.I.) are then stored into the repeaters memory, and the repeater returns to
normal operation.
Please note : This function is not available for domestic DECTappliances, only
PBX.