TEMP, LAMP Indicators

Managing the indicated problems

If a problem should occur with the projector, the TEMP, LAMP indicators will inform you. Manage the indicated problems as follow.

1.Confirm the status of all indicators and projector, and switch off the projector in proper way.

2.Find out the cause of the problem by status of the TEMP, LAMP indicators.

3.Follow the instruction for each indication below and solve the problem.

4.Turn on the projector in the correct way and confirm the indicator is not indicating a problem any longer.

LAMP indicator

TEMP indicator

NOTE:

• If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorised Service Centre.

LAMP indicator

Indicator

Illuminating RED

Flashing RED

 

 

 

 

 

 

 

Problem

LAMP RUNTIME has

LAMP circuit failure, abnormal function or Lamp unit is damaged.

reached 1 800 hours.

 

 

 

 

 

Lamp unit will run out

The POWER is

 

 

 

switched on again

LAMP circuit failure,

Lamp unit is

Cause

soon and needs to be

before the Lamp unit

abnormal function.

damaged.

 

replaced.

 

is cooled enough.

 

 

 

 

 

 

 

See “Replacing the

Let the Lamp unit cool

Contact an Authorised

See “Replacing the

Remedy

Lamp unit” on page 43.

down and turn on the

Service Centre.

Lamp unit” on page 43.

 

 

POWER.

 

 

TEMP indicator

Indicator

Illuminating RED and still projecting

 

Flashing RED and POWER is turned off

 

 

 

Problem

The temperature inside and/or outside the projector is abnormally high.

 

 

 

 

Cause

The ventilation openings are

The room temperature is too

The projector is located at high

covered.

high.

elevations (above 1 400 m).

 

 

Remove the object(s) from the

Reinstall the t a temperature

Turn on the projector*1 and set

 

controlled place.

Remedy

ventilation openings or clear

the HIGHLAND to ON.

See “Specifications” on

 

around the projector.

See “HIGHLAND” on page 38.

 

page 50.

 

 

 

 

 

 

 

*1. The projector will perform only 2 minutes with OFF setting at high elevation.