Warning Indicators

This unit has indicators (lights on the front) to let you know the unit’s internal condition. (P. 10.)

Depending on the condition, the Lamp, Power, or Temp indicator will flash to alert you. In this case, turn unit off and follow the measures below.

 

Indicator

Symptom

Problem

Possible Solution

TEMP

 

 

 

 

Indicator

Flashes red.

Power shuts off.

Internal overheat error.

Wait a while, then turn unit back on.

 

 

 

 

 

POWER

 

 

 

 

Indicator

Flashes orange 1 times.

Power shuts off.

Malfunction 1.

Contact service center.

 

 

 

 

 

 

Flashes orange 2 times.

Power shuts off.

Malfunction 2.

Contact service center.

 

 

 

 

 

 

Flashes orange 3 times.

Power shuts off.

Malfunction 3.

Contact service center.

 

 

 

 

 

 

Flashes orange 4 times.

Power shuts off.

Malfunction 4.

Contact service center.

 

 

 

 

 

 

Flashes orange 5 times.

Power shuts off.

Malfunction 5.

Contact service center.

 

 

 

 

 

 

Flashes orange 6 times.

Power shuts off.

Malfunction 6.

Contact service center.

 

 

 

 

 

 

Flashes orange 8 times.

Power shuts off.

Malfunction 7.

Wait a while, then turn unit back on. If

 

error persists, contact service center.

 

 

 

 

 

 

 

 

 

LAMP

 

 

Lamp will not light or light is

Try turning Power On several times. If

Indicator

Flashes red.

Power shuts off.

abnormal.

error persists, contact service center.

 

 

 

 

 

 

 

 

 

 

OSD appears every

Maximum Lamp life hours

 

 

Light solid red.

time power is turned

Replace Lamp

 

exceeded.

 

 

on.

 

 

 

 

 

 

 

 

 

 

Note:

If unit power is turned back on after performing the appropriate measures, make sure the unit has sufficiently cooled down. If the unit was used for a long period such that the lamp needs enough time to cool down, this may take a while.

Information

65

Page 65
Image 65
Panasonic PT 61DLX75 manual Temp