CONTENTS

Error messages

Error messages

Display

ODescription

OVTR operation and corrective action

 

 

 

 

 

E-20

If condensation is detected, the error number

 

flashes and the unit transfers to eject mode. The

DEW

drum rotates after the cassette is ejected to

 

eliminate the condensation.

 

Once the unit is released from condensation

 

status, the error message display is cleared and

 

the VTR is able to be used.

 

OIf condensation is detected in the eject mode,

 

the drum starts rotating as soon as it is

 

detected.

 

OIf condensation is detected when the cassette

 

has been inserted, the drum rotation is

 

stopped, and after the tape is ejected, the

 

drum starts rotating.

 

VTR: EJECT

 

OLeave the power on and wait.

 

 

E-29

The unit switches to eject mode and if the

 

cassette fails to move up within 6 seconds, this

FRONT LOAD

error number flashes on the display.

MOTOR

OIf the cassette does not move down inside the

 

machine even when 6 seconds have elapsed

 

since the cassette was inserted, the VTR is

 

transferred to the eject mode.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-31

If the unloading operation is not completed

 

within 6 seconds, this error number flashes on

LOADING

the display.

MOTOR

OWhen the loading operation is not completed

 

within 6 seconds, the VTR is transferred to the

 

eject (unloading) mode.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-35

If there is no response from the servo

 

microcomputer for 1 second or more, this error

SERVO

number flashes on the display.

CONTROL

VTR: STOP

ERROR

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-37

If 10 seconds or more elapses and the servo

 

microcomputer has not followed orders issued

SERVO COMM

by the system control microcomputer, this error

ERROR

number flashes on the display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-38

If automatic adjustment of the reel and capstan

 

rotation in eject status was not performed

SERVO FG

correctly when the power was turned on, this

ERROR

error number flashes on the display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

Display

ODescription

OVTR operation and corrective action

 

 

 

 

 

E-51

If the take-up reel rotates without engaging for a

 

specific period of time during the start or end

FRONT LOAD

processing operation while loading is underway

ERROR

(half position), this error number flashes on the

 

display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-52

If the take-up reel fails to take up the tape while

 

the tape is travelling in the state where the total

W-UP REEL

amount of the tape has not yet been detected

NOT ROTA

after the cassette was inserted, this error

 

number flashes on the display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-53

If there is an abnormally large discrepancy

 

between the amount of tape taken up by the

WINDUP

take-up reel and the amount of tape supplied by

ERROR

the supply reel while the tape is travelling after

 

the total amount of the tape begins to be

 

detected, this error number flashes on the

 

display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-55

If the tape has not been taken up during

 

unloading, this error number flashes on the

UNLOAD

display.

ERROR

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-57

If the start or end processing operation is not

 

completed, this error number flashes on the

S-FF/REW

display.

TIMEOVER

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-59

If the cylinder motor speed is abnormally low,

 

this error number flashes on the display.

DRUM ROTA

VTR: STOP

TOO SLOW

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-60

If the cylinder motor speed is abnormally high,

 

this error number flashes on the display.

DRUM ROTA

VTR: STOP

TOO FAST

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-61

If the capstan motor speed is abnormally low,

 

the error number flashes on the display.

CAP ROTA

VTR: STOP

TOO SLOW

OSet the POWER switch to OFF and then to

 

ON again.

 

 

65 (E)