Configuration Options
C-24 3166-A2-GB20-10November 1998

Table C-7. Management Trap Configuration Options (2 of 2)

Entp Trap: Enab
Next Enab Disab Prev
Enterprise Specific Traps. Specifies whether enterpriseSpecific traps are enabled.
Enab – Sends trap messages for enterpriseSpecific events to the currently configured
trap manager(s).
Disab – Disables the sending of trap messages for enterpriseSpecific events.
NOTE: This configuration option is not available if the SNMP Trap configuration
option (in the
Alarm Configuration Options
section on page C-16) is
disabled.
Link Trap: Both
Next Disab Up Down Both Prev
Link Trap Type. Specifies the link trap type to enable. Interfaces monitored for linkUp
and linkDown traps are specified with the Trap I/F configuration option.
Disab – Disables the sending of trap messages for linkDown or linkUp events.
Up – Sends trap messages for linkUp events to the currently configured trap
manager(s).
Down – Sends trap messages for linkDown events to the currently configured trap
manager(s).
Both – Sends trap messages for linkUp and linkDown events to the currently configured
trap manager(s).
NOTE: This configuration option is not available if the SNMP Trap configuration
option (in the
Alarm Configuration Options
section on page C-16) is
disabled.
Trap I/F: Both
Next NET Prt1 Both Prev
Link Trap Interfaces. Specifies which interfaces generate linkUp and linkDown trap
messages.
NET – Sends trap messages for linkUp and linkDown events occurring on the network
interface.
Prt1 – Sends trap messages for linkUp and linkDown events occurring on the
synchronous data port.
Both – Sends trap messages for linkUp and linkDown events occurring on the network
interface or the synchronous data port.
NOTE: This configuration option is not available if the Link Trap configuration option
is not configured to generate trap messages for linkUp or linkDown events.