B. Traps
8000-A2-GB26-50 April 2001 B-3
Loss of Network
Timing major The IDSL port card has
detected that a line supplying
timing to the chassis on the
port designated as NT has
dropped.
24 hot_xdsl.mib
(Hotwire XDSL
interface)
MCC Alarms
Non-supported
chassis
Major The Access Node in Slot

nn

has been installed in a
chassis that cannot support
one or more of its features.
21 hot_sys.mib
(Hotwire system)
Non-supported
MCC warning The Access Node has
detected an MCC release too
low to support this device.
20 hot_sys.mib
(Hotwire system)
Warm start warning Power on reset. 1 MIB II
(RFC 1213)
Selftest failure minor Sent if any portion of the
Access Nodes restart/selftest
fails.
16 hot_sys.mib
(Hotwire system)
SN device
failure major Operating software has
detected an internal device
failure but the Service Node
is operating.
18 hot_xdsl.mib
(Hotwire XDSL
interface)
SN device
mismatch minor Service Node identified on
port
n
does not match device
described in port
configuration role.
07 hot_xdsl.mib
(Hotwire XDSL
interface)
SN device
mismatch clear minor Service Node on port

n

now
matches port configuration
table.
107 hot_xdsl.mib
(Hotwire XDSL
interface)
SN fatal reset Variable binding field contains
device failure code. 20 hot_xdsl.mib
(Hotwire XDSL
interface)
SN loss of
power minor Card received last gasp
message from Service Node,
followed by a link down
condition one minute later.
17 hot_xdsl.mib
(Hotwire XDSL
interface)
SN selftest
failure minor Failure of the Service Nodes
hardware components. This
trap is only sent if the
hardware failure still allows
sending traps.
19 hot_xdsl.mib
(Hotwire XDSL
interface)
Table B-1. DSL Card Traps (3 of 3)
Event Severity Comment Trap # MIB