B. Traps
B-2 April 2001 8000-A2-GB26-50
xDSL link up or
down

or

Transitions
threshold
exceeded
minor Number of link down events
above threshold. This rate is
limited to once every
15 minutes.
1 hot_xdsl.mib
(Hotwire XDSL
interface)
xDSL margin
low minor Margin estimate below
customer set threshold. 3 hot_xdsl.mib
(Hotwire XDSL
interface)
xDSL margin
normal normal Margin estimate now above
customer set threshold. 103 hot_xdsl.mib
(Hotwire XDSL
interface)
xDSL port
failure major Processor detected bad DSL
modem chip set. 5 hot_xdsl.mib
(Hotwire XDSL
interface)
xDSL port
operational normal Processor now
communicating with DSL
modem.
105 hot_xdsl.mib
(Hotwire XDSL
interface)
xDSL port
speed low warning Port speeds decreased to
lower bound thresholds. 2 hot_xdsl.mib
(Hotwire XDSL
interface)
xDSL port
speed normal normal Port speed now above lower
bound threshold. 102 hot_xdsl.mib
(Hotwire XDSL
interface)
xDSL port
speed normal normal Port speed now above lower
bound threshold. 102 hot_xdsl.mib
(Hotwire XDSL
interface)
xDSL SN
selftest fail warning Selftest failure from an
Service Node. 19 hot_xdsl.mib
(Hotwire XDSL
interface)
xDSL test start normal Test started by any means. 6 hot_xdsl.mib
(Hotwire XDSL
interface)
xDSL test clear normal Test over. 106 hot_xdsl.mib
(Hotwire XDSL
interface)
Dynamic filter
injection failure warning Cannot inject or delete
dynamic filters to Service
Node on port

n.

10 hot_dhcp.mib
(Hotwire DHCP
Relay Agent)
Ethernet link
down major 2 MIB II
(RFC 1213)
Ethernet link up normal 3 MIB II
(RFC 1213)

Table B-1. DSL Card Traps (2 of 3)

Event Severity Comment Trap # MIB