Table 6. LEDs (2 of 2)
LED | State | Indication | Additional Information | |
|
|
|
| |
Power | Solid | ENE2020 is operational | If the Power LED is not | |
| Green |
| illuminated, it is unlikely that | |
|
|
| the ENE2020 is receiving | |
|
|
| power and therefore none of | |
|
|
| the LEDs will be illuminated. | |
|
|
|
| |
10/100 | Solid | 100 Mbps Ethernet | If the Ethernet 100 LED is | |
Ethernet | Green | connection is | illuminated, the Ethernet Lnk | |
Connection |
| established | LED will also be illuminated. | |
100 |
|
|
| |
No | No 100 Mbps Ethernet | If the Ethernet 100 LED | ||
| ||||
| Illumination | connection | remains unlit but the Ethernet | |
|
|
| Lnk LED is illuminated then a | |
|
|
| connection has been | |
|
|
| established at 10 Mbps rather | |
|
|
| than 100 Mbps. | |
|
|
|
| |
10/100 | Pulsing* | Standard operation | Traffic is flowing without any | |
Ethernet | Amber |
| problems. | |
Connection |
|
|
| |
Solid | Heavy traffic |
| ||
Act |
| |||
Amber |
|
| ||
|
|
| ||
|
|
|
| |
| No | No activity | Either there is no Ethernet link | |
| Illumination |
| or a link exists but there is no | |
|
|
| activity. | |
|
|
|
| |
10/100 | Solid | Ethernet connection is | If the Ethernet Lnk LED is | |
Ethernet | Green | established | illuminated but not the | |
Connection |
|
| Ethernet 100 LED then a 10 | |
Lnk |
|
| Mbps connection has been | |
|
|
| established. If the Ethernet | |
|
|
| 100 LED is also illuminated, | |
|
|
| then a 100 Mbps connection | |
|
|
| has been established. | |
|
|
|
| |
| No | No Ethernet connection | The Ethernet 100 and Act | |
| Illumination |
| LEDs will remain unlit by | |
|
|
| default. | |
|
|
|
|
*A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more rapid, less constant rate.
11