Reset

Description Setting these bits in an Option Button will effect a feed hold to the Card

This is not an API function but how we effect a Reset

Returns Nothing

Arguments: None

VB Example: Private Sub ResetBtn_Click ()

Call AX_BitOn (130) 'set reset bit …Stop Program and reset to line 0

Auto/Step Mode

Description Setting these bits in an Option Button will place control in Auto/Step mode

This is not an API function but how we effect a Reset

Returns Nothing

Arguments: None

VB Example: To Set control System in Auto Mode

Call AX_BitOn (133) 'Set Auto/Step Mode Bit=1 Call AX_BitOn (134) ' RunMode bit on

To Set control System in Step Mode

Call AX_BitOff (133) 'Set Auto/Step Mode Bit=0 Call AX_BitOn (134) ' RunMode bit on