Introduction / General safety advice for electrical power tools

1 Measuring cup

1 Operating instructions

* 1 x prefitted

QTechnical data

Rated power:

100 W

Delivery capacity:

320 ml / min (water)

Viscosity capacity:

max. 80 DIN-sec

Pressure:

max. 140 bar

Paint cup:

750 ml

Protection class:

II / 

Noise and vibration data:

The sound pressure level (A-weighted) of the device is typically 93.9 dB (A). Uncertainty K = 3 dB. The sound level while working can exceed 106.9 dB (A).

Wear ear protection!

Weighted acceleration, typical: 6.5 m / s2

WarnING! The vibration level given in these instructions has been measured in accordance with a standardised measurement procedure and can be used to compare devices.

Different uses of the device give rise to different vibration levels and in many cases they may exceed the values given in these instructions. In some cir- cumstances it is easy to underestimate the vibration load if the electrical power tool is used regularly.

Note: If you wish to make an accurate assessment of the vibration loads experienced during a particular period of working, you should also take into account the intervening periods of time when the device is switched off or is running but is not actually in use. This can result in a much lower vibration load over the whole of the period of working.

General safety advice for electrical power tools

WarnING! Read all the safety advice and instructions! Failure to observe the safety advice and instructions may result in electric shock, fire and / or serious injury.

KEEP ALL THE SAFETY ADVICE AND INSTRUC- TIONS IN A SAFE PLACE FOR FUTURE REFER- ENCE! THE TERM “ELECTRICAL TOOL” USED IN THE SAFETY ADVICE REFERS TO ELECTRICAL TOOLS POWERED BY MAINS ELECTRICITY (BY MEANS OF A MAINS LEAD) AND ELECTRICAL TOOLS POWERED BY RECHARGEABLE BATTER- IES (WITHOUT A MAINS LEAD).

1. Workplace safety

a)Keep your working area clean and well lit. Untidy or poorly lit working areas can lead to accidents.

b)Do not work with the device in potentially explosive envi-

ronments in which there are inflammable liquids, gases or dusts. Electrical power tools create sparks, which can ignite dusts or fumes.

c)Keep children and other

people away while you are operating the electrical tool.

Distractions can cause you to lose control of the device.

2. Electrical safety

To avoid danger to life from electric shock:

a)The mains plug on the device must match the mains socket. The plug must not be modified in any way. Do not use an adapter plug with devices fitted with a protective earth. Unmodified plugs and matching sockets reduce the risk of electric shock.

GB 7