5.2 LOOP (V.54 & TELCO) DIAGNOSTICS

The NetLink-T1™ offers three V.54 loop diagnostics and is com- patible with two Telco loop diagnostics. Use these diagnostics to test the CSU/DSU and any communication links. These tests can be acti- vated via the software control port (See Section 3.2.3 System Diagnostics), via signals on the serial port interface or the front panel switch.

5.2.1 Operating Local Loopback (LL)

The Local Loopback (LL) test checks the operation of the local NetLink-T1™, and is performed separately on each unit. Any data sent to the local NetLink-T1™ in this test mode will be echoed (returned) back to the user device (i.e., characters typed on the key- board of a terminal will appear on the terminal screen).

 

T1/FT1 CSU/DSU

T1/FT1 CSU/DSU

 

 

Model 2720/I

Model 2720/I

 

 

 

 

 

Ethernet

 

 

 

Receive

Ethernet

Internal

Clocking

Recover

Device

Device

Clocking

 

 

 

Clock/

 

Cable Span

Clock/

 

 

Data

 

Data

Data

Clock/

 

 

Data

Data

Model 2720/X

Model 2720/I

 

 

 

 

LLB Initiated

 

 

 

 

Figure 8. Local Loopback

To perform a LL test, follow these steps:

1.Activate LL. This may be done in one of two ways:

a.Enter a Local Loop from the System Diagnostics/Statistics menu and toggle the <Spacebar>

until “LL” appears next to the a Local Loop option.

b. Toggle the front panel switch to the “Local” position.

2.Verify that the data terminal equipment is operating properly and can be used for a test.

3.Perform a V.52 BER (bit error rate) test as described in Section 5.3. If the BER test equipment indicates no faults, but the data terminal indicates a fault, follow the manufactur- er’s checkout procedures for the data terminal. Also, check the interface cable between the terminal and the NetLink-T1.

37

5.2.2 Operating Remote Digital Loopback (RL)

The Remote Digital Loopback (RL) test checks the performance of both the local and remote NetLink-T1™, as well as the communication link between them. Any characters sent to the remote NetLink-T1™ in this test mode will be returned back to the originating device (i.e, char- acters typed on the keyboard of the local terminal will appear on the local terminal screen after having been passed to the remote NetLink- T1™ and looped back).

 

T1/FT1 CSU/DSU

T1/FT1 CSU/DSU

 

 

Model 2720/I

Model 2720/I

 

 

 

 

 

Ethernet

 

 

 

Receive

Ethernet

Internal

Clocking

Recover

Device

Device

Clocking

 

 

 

Clock/

 

Cable Span

Clock/

 

 

Data

 

Data

Data

Clock/

 

x

Data

Data

Model 2720/I

Model 2720/I

 

 

 

 

 

 

 

RL Initiated

 

 

Figure 9. Local Loopback

There are two Remote Loops that can be initiated from the NetLink-T1 unit: (1) V.54 Loop, and; (2) CSU Loop. The user can select the type of loop that can be initiated from the System Diagnostics/Statistics screen or with Switch S1-1. When a loopback is initiated this is the type of loop that the unit uses to loop up the remote unit. NOTE: The NetLink-T1 will respond to both loops regard- less of the state of the RDL Type.

To perform an RDL test, follow these steps:

1.Activate RDL. This may be done in two ways:

a.Enter b Remote Loop from the System Diagnostics/Statistics menu and toggle the <Spacebar> until “RL” appears next to theb Remote Loop option.;

b.Set the front panel switch to ‘Remote’.

38

Page 20
Image 20
Patton electronic user manual Loop V.54 & Telco Diagnostics, Operating Local Loopback LL, T1/FT1 CSU/DSU, Model 2720/I

2720 specifications

The Patton Electronics 2720 is a versatile and robust solution designed for various networking applications. It serves as a high-performance Ethernet over Copper (EoC) device, enabling the extension of Ethernet connectivity over existing copper lines. This product is particularly beneficial for businesses and organizations looking to enhance their network infrastructure without significant investment in new cabling.

One of the main features of the Patton 2720 is its ability to support multiple Ethernet standards, including 10/100/1000BASE-T. This flexibility allows users to seamlessly integrate the device into an existing network setup, accommodating both legacy and modern equipment. Additionally, the 2720 comes equipped with several Ethernet ports, providing multiple connection options and facilitating the integration of various network devices.

The Patton 2720 employs advanced technologies to ensure reliable performance. It features adaptive equalization, which optimizes the signal quality over copper lines, mitigating potential issues like attenuation and interference. This ensures that even in environments with challenging conditions, users can expect stable and efficient data transmission. Furthermore, the device supports Power over Ethernet (PoE), allowing network cables to deliver both power and data to connected devices, reducing the need for additional power supplies.

In terms of characteristics, the Patton 2720 is designed with a compact form factor, making it suitable for deployment in both residential and commercial settings. Its rugged construction ensures durability, making it capable of withstanding harsh environments. The device is also easy to install and configure, with user-friendly interfaces and management options that simplify setup procedures.

Additionally, the Patton 2720 provides comprehensive network management capabilities, including SNMP support, which allows for remote monitoring and management of the device. This makes it an ideal choice for network administrators seeking robust oversight of their network infrastructure.

In conclusion, the Patton Electronics 2720 stands out as a reliable and feature-rich Ethernet over Copper solution, ideal for businesses looking to optimize their network performance while minimizing costs. Its combination of advanced technologies, flexible connectivity options, and ease of use make it a compelling choice for a wide range of applications.