Model 3034/3038 Getting Started Guide | 4 • Initial configuration |
|
|
Connecting and logging in via the Console port
1.To access the configuration via the console port, connect the
| Model 3038 | PC |
| 192.168.200.10 | |
|
| |
|
| |
Connect to Console port |
| RJ45 to |
Figure 11. Connecting the Model 3034/3038 to your laptop PC via the console port
2.Do NOT connect the device to the Ethernet LAN now.
3.On the PC, start a HyperTerminal session at 19200 bps, 8 data bits, 1 stop bit, no flow control, and no parity.
4.Log into the unit using the following:
login: admin
password:
2. Configuring the desired IP address
Factory-default IP settings
The factory default configuration for the Ethernet interface IP addresses and network masks are listed in table 6. Both Ethernet interfaces are activated upon
Table 6. Factory default IP address and network mask configuration
| IP Address | Network Mask |
|
|
|
LAN interface Ethernet 0 (ETH 0) | 192.168.200.10 | 255.255.255.0 |
|
|
|
LAN interface Ethernet 0 (ETH 0) | 192.168.1.10 | 255.255.255.0 |
|
|
|
LAN interface Ethernet 0 (ETH 0) | DHCP | DHCP |
|
|
|
LAN interface Ethernet 1 (ETH 1) | - | - |
|
|
|
If these addresses match with those of your network, go to section “3. Connecting the Model 3034/3038 to the network” on page 32. Otherwise, refer to the following sections to change the addresses and network masks.
2. Configuring the desired IP address | 31 |