Model 3088 Series User Manual2 • Configuration

DSL Error Monitor

Startup Delay

Interval 1

Interval 2

Interval totint

 

 

 

 

 

 

 

 

 

 

￿ ?startdelay

￿ ?inttime

￿ ?inttime

￿ ?inttime

￿ ?inttime

 

 

 

 

 

The DSL error monitor inspects intervals to see if they have met the error threshold (maxint). If the error mon- itor finds a certain number (intcnt) of intervals that meet or exceed the error threshold, it will restart the DSL link. The error monitor will wait (startdelay) seconds after the DSL link comes up before it begins monitoring errors. After the startup delay, it will check the number of errors that have occurred during each (inttime) sec- onds to see if they meet the error threshold. The error monitor inspects (totint) intervals before it stops.

Note Setting maxint to 0 disables the error monitor and setting totint to 0 causes the error monitor to run continuously.

The following commands configure the error monitor:

dsl set errmon maxint <maxint>: Sets the number of errors allowed in an interval causes it to be consid- ered an errored interval. If this is set to ‘0’, then the error monitor is disabled.

dsl set errmon inttime <inttime>: Sets the length of each interval.

dsl set errmon intcnt <intcnt>: Sets the number of errored intervals that causes the DSL link to restart.

dsl set errmon totint <totint>: Sets the number of intervals to inspect for errors before disabling the error monitor. If this is set to ‘0’, then the error monitor will run continuously.

dsl set errmon startdelay <startdelay>: Sets the number of seconds to wait after the DSL link comes up before the error monitor starts inspecting intervals.

Changing the data rate (dsl set timeslots), the clock mode (system set clockmode), the Annex (dsl set annex), or Line Probe (dsl set lineprobe), or the DSL error monitor settings will not take effect on the DSL link until the link restarts. The dsl start command restarts the DSL link.

DSL Status Command

The dsl show status command shows the following DSL status information: link state, sync state, link speed, error counters, line condition, noise margin, and test mode status.

DSL Clear Errcntrs Command

The dsl clear errcntrs command clears the error counters.

T1/E1 Configuration Commands

t1e1 set linetype <t1-unframedt1-sft1-esfe1-unframede1-fractionale1-crce1-mfe1-crcmf> Select the T1 or E1 framing format to use.

t1e1 set linecode <amihdb3b8zs>

Select the line code to use. HDB3 can only be used for E1 line types, and B8ZS can only be used for T1 line types.

Introduction

37

Page 37
Image 37
Patton electronic 3088 Series user manual DSL Status Command, DSL Clear Errcntrs Command, T1/E1 Configuration Commands

3088 Series specifications

The Patton Electronics 3088 Series is a robust solution tailored for businesses seeking reliable and efficient data connectivity. This series encompasses a range of devices designed to meet the growing demands of modern networking, particularly in environments that require resilient and secure communications.

One of the standout features of the 3088 Series is its versatile connectivity options. The devices support multiple interfaces, including Ethernet and serial connections, allowing for easy integration into existing infrastructures. This flexibility enables organizations to transition smoothly from outdated systems to state-of-the-art technology without extensive reconfiguration.

The 3088 Series also employs advanced protocols to ensure data integrity and security. Mechanisms such as error correction and data encryption are built into the architecture, safeguarding sensitive information from potential breaches. This is particularly important for industries that handle private data, such as healthcare or finance, where compliance with regulations is critical.

In addition to its connectivity features, the 3088 Series prioritizes ease of use and management. Each device is designed with user-friendly interfaces that simplify configuration and monitoring tasks. Comprehensive management options allow network administrators to efficiently track performance, modify settings, and troubleshoot issues remotely, thereby reducing downtime and maintaining productivity.

Furthermore, the 3088 Series emphasizes durability and reliability, making it suitable for demanding applications. Built using high-quality materials, these devices are engineered to withstand environmental stresses, making them ideal for industrial and outdoor deployments. This resilience contributes to lower maintenance costs and longer lifecycle.

The series is also designed with scalability in mind. As businesses grow and their networking needs evolve, the 3088 Series can adapt accordingly. This feature ensures that organizations can expand their capabilities without completely overhauling their systems, providing a cost-effective long-term solution.

Overall, the Patton Electronics 3088 Series stands out as a powerful and flexible platform for data communications. Its combination of versatile connectivity, high-level security features, ease of management, durability, and scalability render it an ideal choice for organizations looking to future-proof their networking infrastructures. As businesses continue to evolve in a digitally driven landscape, the 3088 Series provides a reliable backbone to support their communication needs.