Model 3088 Series User Manual | 3 • |
|
|
Connect twisted pair (120 ohm) to E1 network
The Model 3088/K is equipped with a single
|
| Signal Name | |||
|
| 1 | 1 | (RX) Receive (Ring) | |
|
| 2 | (RX) Receive (Tip) | ||
| |||||
|
| 2 | 3 | Shield | |
| |||||
|
| 3 |
| 4 | (TX) Transmit (Ring) |
|
| ||||
|
| 4 |
| ||
|
|
| |||
|
|
| 5 | (TX) Transmit (Tip) | |
|
|
|
| ||
5 |
| ||||
|
|
|
66 Shield
77 No connection
88 No connection
Figure 13. 120 Ohm RJ-48C E1 interface
Use the following connection diagram to connect the
\
|
| |||
3088/K |
|
|
| E1 (G.703/G.704) |
Signal | Pin # | Network signal | ||
RX (Ring) | 1 |
|
| TX (Ring) |
|
| |||
RX (Tip) | 2 |
|
| TX (Tip) |
|
| |||
Shield | 3 |
|
| Shield |
|
| |||
TX (Ring) | 4 |
|
| RX (Ring) |
|
| |||
TX (Tip) | 5 |
|
| RX (Tip) |
|
| |||
Shield | 6 |
|
| Shield |
|
|
Figure 14. RJ-45 cable diagram for E1 connection
Connecting dual coaxial cable (75 ohm) to E1 network
The Model 3088/K is also equipped with dual female BNCs (TX and RX) for connection to a 75 ohm dual coax E1 network interface. If your E1 network terminates via dual coaxial cable, use figure 15 to make the proper connections.
The interconnecting cables shall be acceptable for external use
and shall be rated for the proper application with respect to volt-
age, current, anticipated temperature, flammability, and
CAUTION mechanical serviceability.