O P E R A T I N G I N S T R U C T I O N S

CAUTIONS

The unit must be disconnected from the AC power source before any work is done on it. Refer all servicing to qualified service personnel.

The heat sink on the back plate can become hot to the touch. Do not block or cover the heat sink from ventilation.

Be sure to keep the microphone away from the front of the speaker after switching the mic sensitivity pad to the OUT position and while setting the microphone level or very loud feedback will occur! Damage to the system is likely if this occurs!

DO NOT connect the inputs of the PR10P to the output of a power amplifier. The inputs are meant to be driven from a line-level strength signal.

DO NOT remove the protective metal grille.

Warning: The PR 10P is very efficient and powerful! This sound system can permanently damage hearing! Use extreme care setting the overall maximum loudness!

The apparent sound level of the PR 10P can be deceiving due to its clear, clean sound output. The lack of distortion or obvious distress can make the sound level seem much lower than it actually is. This system is capable of SPL in excess of 119 dB at 1 M from the speaker!

Flying the PR 10P

Caution: The suspending or flying of the Peavey PR 10P must be done by a certified structural engineer.

Important Safety Information for Mounting the Peavey PR 10P speaker system

Caution: Before attempting to suspend this model of speaker, consult a certified structural engineer. Speaker can fall due to improper suspension, resulting in serious injury and property damage. Other enclosures must not be suspended below one, nor should additional weight be suspended from one of these units. Use only the correct mating hardware. All associated rigging is the responsibility of others.

Always use all four inserts of a given group as a set, NEVER use just one insert to fly a cabinet! The four insert groupings are a top group of four and a bottom group of four. Some models also have a group of four on the rear plane of the cabinet.

Maximum enclosure angle from vertical hang: 30˚

Always use a suitable safety chain or wire rope, looped through the top handle, and firmly attached to a suitable structural member as indicated by a certified structural engineer.

The recommended range of torque for the mounting bolt is 3 to 3-1/2 lb./feet of torque. DO NOT OVERTIGHTEN! If an insert spins, it has been damaged and the cabinet can not be flown!

Never transport the cabinet while mounted on an array bracket or other mounting bracket, as this may unduly stress the mounting inserts.

WARNING! (note to structural engineer)

For the PR 10P, the thread insertion depth of the end of the mounting bolt should not be more than 5/16" past the surface of the cabinet.

If these thread insertion depths are exceeded, then the inserts may be damaged or unseated from the cabinet, severely compromising the mounting integrity of the cabinet!

The correct mounting bolt diameter and threads per inch are: 1/4" X 20. Use of a grade five-bolt is recommended.

7

Page 7
Image 7
Peavey manual E R a T I N G I N S T R U C T I O N S, Flying the PR 10P