CHARGING THE HYDRAULIC SYSTEM

!DANGER

DO NOT EXCEED MORE THAN 10 POUNDS OF PRESSURE WHEN CHARGING THE HYDRAULIC SYSTEM. FAILURE TO DO SO MAY RESULT IN SYSTEM FAILURE AND/OR PERSONAL INJURY.

CONTACT YOUR BRUSH BLAZER DEALER FOR THE HYDRAULIC CHARGING KIT ORDERING INFORMATION:

?HYDRAULIC CHARGING KIT (PART#: TBB2-0068) INCLUDES:

(1)1/4” AIR REGULATOR WITH GAUGE (PART#: TBB2-0067)

(1)1/4” FEMALE COUPLER (PART#: TBB2-0066)

(1)1/4” MALE PLUG (PART#: TBB2-0063)

(1)HYDRAULIC OIL TANK CAP WITH FITTING (PART#: TBB2-0065) INCLUDES:

(1)HYDRAULIC OIL TANK CAP DRILLED FOR 1/4” NPT (PART#: TBB2-0064)

(1)1/4” MALE PLUG (PART#: TBB2-0063)

TOOLS REQUIRED:

(1) AIR COMPRESSOR

(1)AIR HOSE WITH 1/4” FEMALE COUPLER

(1)CONTAINER FOR COLLECTING FLUID

(1)HYDRAULIC CHARGING KIT

PROCEDURE:

1.Loosen, but do not remove the charge relief valve on both hydraulic pumps. Figure 1

2.Disconnect the return line. Attach a hose to the end of the return line and use a suitable container to collect any fluid leakage that may occur. Figure 2

LOOSEN THE

CHARGE

DISCONNECT RETURN

RELIEF VALVE

LINE AND ATTACH HOSE

TO CONTAINER

FIGURE 1

FIGURE 2