Pelco C3407M-D manual Camera Adjustments, Varifocal Lens Zoom And Focus Adjustments

Models: C3407M-D

1 24
Download 24 pages 2.82 Kb
Page 13
Image 13
Camera Adjustments

Camera Adjustments

To perform the following camera adjustments, make sure to plug in the camera and service connectors. You may have to remove the camera module from the back box.

Connect a monitor. Then turn on power to the camera and monitor. To use the service connector, refer to Service Connector on page 18.

To adjust the DIP switches or the vertical phase, you will need a miniature trimpot adjustment tool with a 0.05-inch (1.27 mm) blade. Suggested tools include a miniature flat-tip screwdriver, a Philmore trimpot tool (#63-6808), and the Philmore 10-piece tool set (#63-910).

After you have adjusted the unit, reinstall the camera module into the back box, and install the trim ring, bubble, and dome liner (if necessary).

NOTES:

The electronics of the ICS150-CW automatically adjust the camera to the auto iris. Auto iris level adjustments are not necessary.

The R7 adjustment is reserved.

VARIFOCAL LENS ZOOM AND FOCUS ADJUSTMENTS

To adjust the field of view and the focus:

1.Select a field of view by turning the zoom adjustment ring clockwise/counterclockwise (refer to Figure 8).

2.Tighten the zoom locking screw.

3.Adjust the focus by moving the focus locking screw clockwise/counterclockwise.

4.Tighten the focus locking screw.

FOCUS

ZOOM

Figure 8. Location of Zoom and Focus Adjustments