16 C613M-A (5/05)
Refer to Table C when installing the PTZ device. It lists the serial port settings that the SP04-140 supports.
Table C.
Serial Port Options and Defaults
CONNECTING A RELAY DEVICE
The SP04-140 has an output for triggering an external device. It supports both momentary and continuous relay operation.
You can operate the relay interactively, during an active connection, or automatically to coincide with certain events. Typical applications include
activating a door, gate or lock, or switching on lights or other electrical devices.
Figure 13 shows how to wire the relay with its power source to the video encoder (refer to Table B for the speciļ¬c connector pin assignments).
Figure 13.
Connecting a Relay Device
Setting Options Default
Data rate (bits per
second)
110, 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200, 230400 2400
Data bits 5, 6, 7, 8 8
Parity None, Odd, Even None
Stop bits 1, 2 1
WARNING:
Do not exceed the maximum rating of 30 VDC, 1 A.
LOAD:
LIGHT/SIREN
EXTERNAL
FUSE
POWER
MAX 30 VDC, 1 A
NO C