12 C613M-A (5/05)
Before installing the SP04-140, make sure the distance from the unit to the video device is less than the maximum distance for the coaxial cable.
Refer to Table A for maximum video coaxial cable distances.
Table A.
Video Coaxial Cable Requirements
*Cable requirements:
75-ohm impedance
All-copper center conductor; steel-center conductor cable may result in poor performance
All-copper braided shield with 95% braid coverage
NOTE:
Make sure the termination switch is set to 75
to enable termination. This is the default.
To connect a fixed camera:
1. Connect a coaxial cable to the camera device.
2. Connect the coaxial cable to the video in (1) connector on the rear panel.
To connect a second fixed camera:
1. Connect a coaxial cable to the camera device.
2. Connect the coaxial cable to the video in (2) connector on the rear panel.
To connect a PTZ device:
1. Connect a coaxial cable to the PTZ device.
2. Connect the coaxial cable to the video in (2) connector.
3.
Pelco D only:
Wire the TX and RX leads from the encoder to the PTZ device. Refer to
Connecting a PTZ Device (Pelco D Protocol)
.
Cable Type* Maximum Distance
RG59/U 750 ft (229 m)
RG6/U 1,000 ft (305 m)
RG11/U 1,500 ft (457 m)