Troubleshooting

Troubleshooting

LED indicators on the front panel of the FT106011 transmitter/FR106011 receiver (refer to Figure 2) allow you to monitor signal status, laser status, data activity, contact closure activation, and operating power. Table F provides information about the front-panel indicators and associated troubleshooting guidelines.

Table F. Troubleshooting with Front-Panel Indicators

Indicator Color

Meaning

Possible Cause

Corrective Action

 

 

 

 

 

Power LED (Pelco badge)

 

Blue

Not lit

Power is being applied

No action required.

to the module.

 

 

Power is not being

Power connection is

Check power connection.

applied to the module.

faulty.

If module is rack mounted,

 

 

reseat module or power

 

 

supply as necessary.

 

 

 

 

Power supply has failed.

Replace power supply.

 

 

 

 

Loss of power occurs due

Check circuit breaker(s),

 

to tripped circuit

fuse(s), or electrical service

 

breaker(s), blown fuse(s),

as necessary.

 

or faulty electrical

 

 

service.

 

 

 

 

Amber

Not lit

Contact Closure LED (

)

 

Contact is closed.

 

No action required.

Contact is open.

 

No action required.

 

 

 

 

Connections are faulty.

Check connections.

 

 

 

 

(Continued on next page)