FR85011A

 

 

 

 

 

DEVICE A

 

 

 

 

 

RECEIVER –

 

 

 

 

 

RS-422

DATA CONNECTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RX+

 

 

 

 

 

 

 

 

1

TX+ (DATA OUT+)

 

RS-422

RX-

 

 

 

 

 

 

 

 

 

 

2

TX-

(DATA OUT-)

DATA SELECTION

 

 

 

 

 

 

 

 

TX+

 

 

 

 

 

 

 

 

 

 

3

RX+ (DATA IN+)

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TX-

 

 

 

 

 

 

 

 

 

 

4

RX-

(DATA IN-)

 

 

 

 

 

 

 

 

 

0

 

 

5

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

8

7

6

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

8 GND

RS-422 DATA CONNECTIONS BETWEEN DEVICE A AND FR85011A RECEIVER

 

 

 

 

 

 

FT85011A

 

 

 

 

 

 

 

 

TRANSMITTER –

 

 

 

 

 

DEVICE B

RS-422

DATA CONNECTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RX+

 

 

 

 

 

 

1

TX+ (DATA OUT+)

 

RS-422

RX-

 

 

 

 

 

 

2

TX-

(DATA OUT-)

DATA SELECTION

 

 

 

 

 

TX+

 

 

 

 

 

 

3

RX+

(DATA IN+)

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

TX-

 

 

 

 

 

 

4

RX-

(DATA IN-)

 

 

 

 

 

 

0

 

 

5

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

9

8

7

6

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

GND

RS-422 DATA CONNECTIONS BETWEEN DEVICE B AND FT85011A TRANSMITTER

Figure 8. RS-422 Data Communication Wiring

C2604M (7/06)