Pelco FR85011A manual Manchester Data Communication Wiring

Models: FR85011A

1 32
Download 32 pages 35.09 Kb
Page 22
Image 22

DEVICE A

W*

B*

 

FR85011A

 

 

 

 

 

 

RECEIVER –

 

 

 

 

 

 

DATA CONNECTOR

 

 

 

 

 

MANCHESTER

 

 

 

1

 

 

MANCHESTER

 

 

 

 

 

 

2

 

 

DATA SELECTION

 

 

 

 

 

 

3

RX+

(DATA IN+)

 

2

3

4

 

 

 

 

 

 

 

 

4

RX- (DATA IN-)

0

 

 

5

 

 

5

 

 

 

 

 

 

 

 

9

8

7

 

SHIELD

 

6

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

GND

MANCHESTER DATA CONNECTIONS BETWEEN DEVICE A AND FR85011A RECEIVER

 

 

FT85011A

 

 

 

 

 

TRANSMITTER –

 

 

 

DEVICE B

DATA CONNECTOR

 

 

 

 

 

 

 

1

MANCHESTER

 

 

 

 

 

MANCHESTER

 

 

2

DATA SELECTION

W*

 

 

3

1

2

3

4

 

 

 

 

 

B*

 

 

 

4

 

 

 

 

 

0

 

 

5

 

 

 

5

 

 

 

 

 

 

9

8

7

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

7

TX+ (DATA OUT+)

 

 

 

 

 

 

 

 

 

 

SHIELD

 

 

8

TX- (DATA OUT-)

 

 

 

 

 

GND

 

 

 

MANCHESTER DATA CONNECTIONS BETWEEN DEVICE B AND FT85011A TRANSMITTER

*W DENOTES WHITE WIRE, AND B DENOTES BLACK WIRE.

Figure 11. Manchester Data Communication Wiring

22

C2604M (7/06)

Page 22
Image 22
Pelco FR85011A manual Manchester Data Communication Wiring