Pelco ICS210 manual 24 VAC, 12 VDC, b.Use a screwdriver to remove the conduit cover

Models: ICS210

1 20
Download 20 pages 14.14 Kb
Page 9
Image 9
b.Use a screwdriver to remove the conduit cover.

5.Pull wiring through the conduit opening (refer to Figure 8):

a.Use a 1/16” hex head wrench to loosen the hex head inset screw.

b.Use a screwdriver to remove the conduit cover.

c.Pull the power wires and video cable through the conduit opening.

CONDUIT COVER

HEX HEAD INSET

SCREW

1/16" HEX HEAD WRENCH

Figure 8. Removing the Conduit Cover

6.Install a 0.75-inch (1.91 cm) conduit connector in the conduit opening. Line up the mounting holes in the base with the mounting holes of the mounting plate. Attach the base to the mounting plate with the three 8-32 x 0.375-inch screws and lock washers previously removed.

7.Attach the base to the conduit and then connect the power input wires to the power wires of the ICS210 Camclosure. Refer to the following to connect the power wires:

24 VAC:

Connect power to the red and blue wires. The black wire is not used.

12 VDC:

a.Connect +12 VDC to the red wire and ground to the black wire. The blue wire is not used.

b.Reset the voltage jumper located on the camera power board inside the base of the Camclosure. Refer to Figure 5. Remove the jumper from AC position and reinstall the jumper on the DC position.

8.Connect the video cable. Make sure the boot covers the BNC connectors. Push the power wires and video cable back through the conduit fitting.

C2491M-D (8/06)

9

Page 9
Image 9
Pelco ICS210 manual 24 VAC, 12 VDC, b.Use a screwdriver to remove the conduit cover