Pentair C40 Electrical Specifications and 110 VAC and 220 VAC Wiring, IntelliChlor Model IC20

Models: C20 C40

1 13
Download 13 pages 20.1 Kb
Page 10
Image 10
Electrical Specifications and 110 VAC and 220 VAC Wiring

5

Electrical Specifications and 110 VAC and 220 VAC Wiring

Circuit Protection: Two-pole 20 AMP device at the electrical panel.

IntelliChlor Model IC20

Input: 90-130 VAC, 50/60 Hz, 220 Watts (2 AMP) or 220-240 VAC, 50/60 Hz, 220 Watts (1 AMP).

Output: 22-39 VDC @ 6 AMPS maximum from the Power Center.

Chlorine: 0.70 lb. / 24 hour. (317 gm / 24 Hour).

IntelliChlor Model IC40

Input: 90-130 VAC, 50/60 Hz, 220 Watts (2 AMP) or 220-240 VAC, 50/60 Hz, 220 Watts (1 AMP).

Output: 22-39 VDC @ 6 AMPS maximum from the Power Center.

Chlorine: 1.40 lb. / 24 Hour (635 gm / 24 Hour).

IMPORTANT: When using IntelliChlor with an IntelliTouch system, it is recommended to wire the Power Center to the pump side of the relay located in the IntelliTouch Load Center. This method does not require a ground fault circuit-interrupter (GFCI) to protect the circuit.

220 VAC Basic System Wiring

110 VAC Basic System Wiring

IntelliChlor Power Center Installation Guide

Page 10
Image 10
Pentair C40 Electrical Specifications and 110 VAC and 220 VAC Wiring, VAC Basic System Wiring 110 VAC Basic System Wiring