2

Operating Instructions

When using a pool pump timer: The Association of Pool and Spa Professionals (APSP) recommends that all water in a residential pool pass through the filtration system at least once every 12 hours (referred to as pool water turnover). However, many factors have an effect on actual pump and filter system run times. Pool size, source of water, direct sun light, indoor/outdoor, screened and unscreened, filtration system, cold or hot weather, swimmer load, rain, organic debris, algae, etc., are all factors which contribute to either more or less pool pump and filter system run times. Because of these differences, it is extremely difficult to set an initial run time (starting point) for the pool pump and chlorinating system.

Try initially setting the pool pump timer to 12 hours. It will take a few days to get just the right amount pool pump operating time. When the Chlorinator is wired with a pool pump timer (see page 6) results will vary

greatly from one pool installation to the next, so this should be discussed with either the pool builder or your pool professional.

Installation

The following information describes how to install the IntelliChlor Power Center. Before installing, review the IntelliChlor kit contents and required tools. For cell installation instructions, see the “IntelliChlor User’s Guide” (P/N 520584).

Kit Contents

-One Power Center

-Installation Guide (this manual)

Required Tools

-Phillips & Flathead Screwdrivers

-Voltmeter. (To determine AC line voltage to Power Center)

-Electric drill and 1/4" masonry drill bit. (To mount Power Center)

WARNING! IMPORTANT SAFETY PRECAUTIONS. PLEASE READ THE FOLLOWING: Read all the safety precautions in this manual before attempting any electrical wiring. Be sure to read and follow all safety Instructions on page ii. Wiring should only be performed by a qualified professional. When using electrical products, basic precautions should always be followed, including the following:

WARNING! RISK OF ELECTRIC SHOCK,WHICH CAN RESULT IN SERIOUS INJURY OR DEATH. Before attempting installation of service, ensure that all power to the circuit supplying power to the system is disconnected/switched off at the circuit breaker. When using IntelliChlor with an IntelliTouch system, it is recommended to wire the IntelliChlor Power Center to the pump side of the relay located in the IntelliTouch Load Center. This wiring method does not require a ground fault circuit-interrupter (GFCI) to protect the circuit. A green colored terminal (or a wire connector marked “G”, “GR”, “Ground” or “Grounding”) is provided within the terminal compartment in the Power Center transformer enclosure. To reduce risk of electric shock, connect this terminal or connector to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying this equipment. The power supply must be interconnected with pool pump motor power source. This insures the IntelliChlor chlorinator and pool pump will switch on and off together.

Grounding (earth bonding) is required. The unit should be installed by a qualified service person and grounded.

CAUTION - Install the IntelliChlor unit a minimum of two (2) feet from the heater outlet.

Allow ample access to the IntelliChlor control panel buttons and the IntelliChlor Power Center.

Pipe couplings: Schedule 80, maximum pressure 150 psi at 70° F.

Operate unit with minimum flow of 20 gpm. For high flow applications, use a bypass loop.

IntelliChlor Power Center Installation Guide

Page 7
Image 7
Pentair C20, C40 important safety instructions Operating Instructions, Installation

C20, C40 specifications

Pentair C20 and C40 are high-performance filtration systems designed for both residential and commercial applications. They provide water treatment solutions that enhance water quality while maintaining efficiency and ease of use.

The C20 model is specifically optimized for smaller applications, such as residential homes or light commercial use. It features a compact design that allows for easy installation in limited spaces. The system operates with a maximum flow rate of up to 20 gallons per minute, making it ideal for households with moderate water consumption. The C20 utilizes a multi-stage filtration process that includes sediment filtration, activated carbon, and UV sterilization, ensuring that contaminants and impurities are effectively removed from the water supply.

On the other hand, the C40 model is designed for larger-scale applications, catering to high water usage settings such as commercial buildings, restaurants, and industrial facilities. The C40 system boasts a greater flow rate of up to 40 gallons per minute, making it powerful enough to handle the demands of larger operations. Like the C20, the C40 employs a multi-stage filtration approach, but it includes additional filtration mediums to address a wider range of contaminants including chlorine, heavy metals, and microorganisms.

Both the C20 and C40 incorporate advanced technologies such as smart monitoring systems, which allow users to track filter performance and water quality in real time. This feature not only aids in maintenance scheduling but also ensures that the system operates at peak efficiency. The systems are equipped with user-friendly interfaces that provide alerts for filter replacement and maintenance needs.

Durability is another hallmark of the Pentair C series. Both models are constructed using high-quality materials that resist corrosion and wear, ensuring a long lifespan. The units also feature quiet operation, making them suitable for residential areas where noise can be a concern.

Overall, Pentair C20 and C40 represent a blend of technological innovation and practical design, providing users with reliable water filtration solutions that enhance their quality of life. These systems exemplify Pentair's commitment to improving water quality while being mindful of environmental sustainability. Whether for a home or a larger commercial entity, the C20 and C40 models deliver unmatched performance and efficiency.