Perle Systems S-10G-XTX manual LK1- Port 1 Activity, LK2 - Port 2 Activity, LK1 LK2 Error Codes

Models: S-10G-STS S-10G-XTXH S-10G-XTS S-10G-XTX S-10G-XTSH

1 16
Download 16 pages 41.41 Kb
Page 11
Image 11

LK1- Port 1 Activity

On: Fiber link present.

Blinking quickly: Fiber link present and receiving data.

Blinking slowly: The fiber link has been taken down as a result of Smart Link Pass-Through.

Blinking one second on, 3 seconds off: the maximum specified operating temperature within the inserted module has been exceeded.

Off: No fiber link present.

LK2 – Port 2 Activity

On: Fiber link present.

Blinking quickly: Fiber link present and receiving data.

Blinking slowly: The fiber link has been taken down as a result of Smart Link Pass-Through.

Blinking one second on, 3 seconds off: the maximum specified operating temperature within the inserted module has been exceeded.

Off: No fiber link present.

LK1 LK2 Error Codes

LK1

LK2

Meaning

 

 

 

Off

Off

Incompatible SFP+ or XFP or speed mismatch on SFP+

 

 

 

Off

On

Power Budget exceeded – XFP’s requesting more power than

 

 

specified port rating.

 

 

 

On

Off

SFP+ or XFP communication error – S-10G unable to

 

 

communicate with module

 

 

 

On

On

Internal Error

 

 

 

Grounding the S10-G Chassis

If your installation requires additional grounding follow this procedure.

Grounding the chassis requires the following items:

One grounding lug (not provided)

One 18-12 AWG wire (not provided)

Perle S- 10G Media Converter Installation Guide

11

Page 11
Image 11
Perle Systems S-10G-XTX LK1- Port 1 Activity, LK2 - Port 2 Activity, LK1 LK2 Error Codes, Grounding the S10-G Chassis