SPD- (Copper Port)

Green – 1000 Mbps

Orange – 100 Mbps

Off – 10 Mbps (if link is currently established)

FDC- (Duplex on Copper)

On – Full Duplex Mode

Off – Half Duplex Mode

LKC- (Link Status on Copper port)

On – Copper link is present

Off – No copper link present

Blinking (slow) – Copper link appears functional – Copper link has been brought down by Smart Link Pass-Through.

Blinking (fast) – Copper link up and receiving data

Troubleshooting

General

1.Ensure power source is connected.

2.Ensure the remote device’s fiber connection type is compatible with the media converter. If using a simplex fiber connection, ensure that you have both an Upstream

(U) and Downstream (D) media converter.

3.Ensure all cabling is of the correct type and is in good working order.

4.For duplex fiber connections, ensure the RX and TX has been reversed between the two media converters.

No connectivity

If unable to get full connectivity with all DIP switches in the UP position, this procedure is recommended for troubleshooting.

Perle 10/100/1000 Ethernet Extended Temperature Media Converter

13

Installation Guide

 

Page 13
Image 13
Perle Systems S-1110-XT manual Troubleshooting General, No connectivity