Installing the Simplex Fiber Cable

1.Locate a 1000Base-X compliant simplex (1 strand) fiber cable with appropriate connectors. Ensure that the TX wavelength matches the RX wavelength at the other end and the RX wavelength matches the TX wavelength at the other end.

2.Connect the fiber cable from one media converter to the other media converter/switch/fiber device.

Installing the Copper Cable

1.Locate 10/100/1000Base-T compliant copper cables with the appropriate connectors.

2.Connect the RJ-45 cable between the Perle media converter and the device.

Note: The Perle media converter supports Auto-MDIX which allows connection of a straight-through or cross-over Ethernet cable. See Auto-MDIX Jumper Settings in this guide for jumper positions.

Grounding the Media Converter

If your installation requires additional grounding this procedure can be followed.

Grounding the chassis requires the following items:

One grounding lug (not provided).

Grounding wire 12 to 18 AWG (not provided).

Cross-head screwdriver (not provided).

Note: For your safety, when installing this equipment, always ensure that the chassis ground connection is installed first and disconnected last.