Server Commands

 

pre-4.3g data-logging

 

Enable the data logging feature previous toV4.3 firmware.

 

Default: Disabled

 

udp-always-arp

 

This controls whether the IOLAN will attempt an ARP each time there is data to be

 

transmitted and the ARP table does not have a valid ARP entry for the destination.

 

When set to "off", a new ARP will only be attempted after a timeout period. Any data

 

to be sent before the timeout elapses, will be silently discarded.

 

Default: Off

Set Service

 

Description

Sets server service parameters.

User Level

Admin

Syntax

set service [telnetd onoff] [httpd onoff] [snmpd onoff]

 

[spcd onoff] [syslog onoff] [dmgrd onoff] [modbusd onoff]

Options

telnetd

 

Telnet daemon process in the IOLAN on port 23.

 

httpd

 

HTTP daemon process in the IOLAN on port 80.

 

snmpd

 

SNMP daemon process in the IOLAN on port 161.

 

spcd

 

SPC (Trueport) daemon process in the IOLAN on port 668.

 

syslog

 

Syslog client process in the IOLAN.

 

dmgrd

 

DeviceManager daemon process in the IOLAN. If you disable this service, you will not

 

be able to connect to the IOLAN with the DeviceManager application.

 

DeviceManagerD listens on port 33812 and sends on port 33813.

 

modbusd

 

Modbus daemon process in the IOLAN on port 502.

Show Custom-App

 

Description

Shows the custom application server settings.

User Level

Admin

Syntax

show custom-app server

Show Modbus

 

Description

Shows the Modbus settings for the gateway.

User Level

Normal, Admin

Syntax

show modbus gateway

Show Server

 

Description

Shows the parameters set for the server.

19

Page 18
Image 18
Perle Systems TS2, DS1 manual Set Service, Show Custom-App, Show Modbus, Show Server

DS1, TS2 specifications

Perle Systems TS2 and DS1 are advanced serial-to-Ethernet devices designed to facilitate seamless integration of serial devices with modern IP networks. These devices serve as crucial tools for businesses looking to enhance their communication capabilities while leveraging existing infrastructure.

One of the standout features of the Perle TS2 and DS1 is their ability to support multiple serial protocols including RS232, RS422, and RS485. This versatile support allows businesses to connect various legacy devices to their networks, ensuring that critical equipment can still communicate effectively in an increasingly digital landscape.

The TS2 model is particularly noted for its dual serial ports, enabling simultaneous communication with multiple devices. This capability is invaluable for applications requiring real-time data transmission, such as remote monitoring and automated control systems. The DS1 model, on the other hand, is designed for single-port use, making it an ideal solution for smaller-scale operations or specific single-device connections.

Both the TS2 and DS1 incorporate advanced features such as configuration through a web interface, which simplifies setup and management. Users can easily access device settings and monitor performance metrics remotely, enhancing operational efficiency. These devices also support various network protocols such as TCP/IP, UDP, and ICMP, ensuring compatibility with a wide range of network architectures.

In terms of security, Perle Systems prioritize user data protection. The TS2 and DS1 offer features including SSL encryption and SSH protection, providing an added layer of security for sensitive information transmitted over the network. This is particularly important for industries where data integrity and security are paramount, such as healthcare and finance.

Additionally, the rugged design of both devices ensures reliable performance even in harsh environments. With extended temperature ratings and robust housing, the TS2 and DS1 can operate in diverse conditions without compromising functionality.

To summarize, the Perle Systems TS2 and DS1 provide a reliable and flexible solution for connecting legacy serial devices to modern networks. With their support for multiple serial protocols, web-based management, robust security features, and rugged design, these devices cater to a variety of industries looking to modernize their communication infrastructure while maintaining existing equipment. Whether for large-scale operations or smaller implementations, the TS2 and DS1 equip businesses with the tools needed for effective serial communication in an IP-driven world.