Perlick BBRN Troubleshooting, Before Calling For Service, power to the unit has been disconnected

Models: BBSN BBRN

1 24
Download 24 pages 3.52 Kb
Page 12
Image 12
Troubleshooting

Models BBRN/BBSN Installation & Operation Manual

Troubleshooting

Before Calling For Service

If the unit appears to be malfunctioning, read through the Operation section in this manual first. If the problem persists, check through this troubleshooting section. Locate the problem and refer to the cause and remedy before calling for service. The problem could be something that can be solved without a service call.

 

Never attempt to repair or perform maintenance on the unit until the main electrical

DANGER

 

 

 

power to the unit has been disconnected!

 

 

 

 

 

 

Problem

 

Cause

 

Solution

 

No interior light.

 

Rocker switch in Off position.

 

Turn switch on.

 

 

 

 

LED board inoperable.

 

Contact your selling dealer.

 

Light stays on when door is

Manual switch on.

 

Turn manual switch off.

 

closed.

 

 

 

 

 

Noisy operation.

 

Soft sounds from compressor, fan

 

Normal operation.

 

 

 

 

motor and valves heard.

 

 

 

LED Controller display is flashing

Thermostat probe failure.

 

Contact your selling dealer.

 

.“P1”.

 

 

 

 

 

LED Controller display is flashing

Internal compartment has exceeded the

 

Make sure door is completely closed.

 

“HA”.

 

high temperature alarm preset value for

 

Check door gasket seal. Replace if

 

 

 

 

over 30 minutes.

 

necessary.

 

 

 

 

 

 

Check condenser and clean if necessary.

 

 

 

 

 

 

Make sure louvered plate is unobstructed.

 

 

 

 

 

 

If surrounding ambient temperature has

 

 

 

 

 

 

changed dramatically recently, compartment

 

 

 

 

 

 

temperature may be affected.

 

 

 

 

 

 

Make sure interior light is off.

 

 

 

 

 

 

Warm product placed in cabinet recently. Wait

 

 

 

 

 

 

24 hours for product to chill then recheck

 

 

 

 

 

 

temperature.

 

LED Controller display is flashing

Internal compartment has exceeded the

 

Make sure door is completely closed.

 

“LA”.

 

low temperature alarm preset value for

 

Check door gasket seal. Replace if

 

 

 

 

over 30 minutes.

 

necessary.

 

 

 

 

 

 

If surrounding ambient temperature has

 

 

 

 

 

 

changed dramatically recently, compartment

 

 

 

 

 

 

temperature may be affected.

 

LED Controller display is flashing

Controller has a data or memory failure.

 

Reset both compartment presets.

 

“EE”.

 

 

 

If problem persists, contact your Perlick

 

 

 

 

 

 

Service Department.

 

Unit is not running.

 

No power to the unit.

 

Home circuit breaker tripped. Reset circuit

 

 

 

 

 

 

breaker.

 

 

 

 

 

 

ON/OFF keypad is off. Turn on.

 

 

 

 

Condenser dirty.

 

Clean the condenser.

 

Compartments are warmer than

Control preset not set properly.

 

Reset compartments presets.

 

usual.

 

Light staying on.

 

Turn manual light switch off.

 

 

 

 

Condenser dirty or obstructed.

 

Clean condenser and clear obstruction.

 

 

 

 

Door is open or has been opened more

 

Wait 24 hours and recheck temperature.

 

 

 

 

frequently lately.

 

Reset preset temperature if necessary.

 

 

 

 

Internal louvers and/or fan guard

 

Make sure louvers and/or fan is not

 

 

 

 

obstructed.

 

obstructed.

 

 

 

 

Warm product placed in cabinet

 

 

 

 

 

 

recently.

 

 

 

Printed in USA

12

0213

Page 12
Image 12