Perlick DC72S, DC96S Installation and Operating Instructions, Model Nos, dC72S, dC84S, dC96S

Models: DC72S DC96S DC84S

1 12
Download 12 pages 38.65 Kb
Page 2
Image 2
Installation and Operating Instructions

Installation and Operating Instructions

Sizes and Specifications, Concessionaire Dispensers

Model Nos.

 

dC72S

dC84S

dC96S

keg capacity

2 Keg

3 Keg

4 Keg

CABINET

Length Ins. (mm)

72” (1829)

84” (2134)

96” (2438)

Dimensions

 

 

 

 

 

Depth Ins. (mm)

243/4” (629)

243/4” (629)

243/4” (629)

 

w/o Bumpers

Height Ins. (mm)

341/2” (876)

341/2” (876)

341/2” (876)

No. of dispensing heads

1

1

2

 

No. faucets

 

2

2

2

 

condenser unit h.p.

1/4

1/3

1/3

 

running load - amps

5.9

7.5

7.5

 

Ship wt lbs. (kg)

445 (202)

505 (229)

545 (247)

 

Interior

 

Door sill: High strength polyethylene. Door pan and ceiling: High strength polystyrene.

 

 

Floor pan: Satinless steel. Walls: Galvanized steel.

 

 

exterior

 

All Models: The top is stainless steel. The back, front and sides are stainless steel. Bottom is

 

 

galvanized steel. Doors and grilles are stainless steel.

 

 

 

 

 

 

 

Refrigeration

R-134a capillary tube-type. Aluminum fin and copper tube evaporator, epoxy coated coil. Forced air

 

 

into dispensing head. Adjustable temperature control. Self-defrosting. Pull-out condensing unit for

 

 

service and cleaning.

 

 

 

 

 

 

 

 

 

Ventilation

 

Front ventilated.

 

 

 

electrical

 

115 Volt, 60 Hz., 1 Phase AC. Furnished with three prong, six foot NEMA5-15P cord.

 

 

Contact Perlick for other voltage/frequency requirements.

 

 

 

 

 

 

 

 

Plumbing

 

Evaporator condensate has been plumbed to a condensate pan located in the compressor housing.

Insulation

 

Foamed-in-place polyurethane; 2” walls, 11/2” top and floor.

 

 

 

 

 

 

 

 

OPTIONAL ACCESSORIES

• Keg Couplers

• Faucet Locks

 

 

 

 

• Regulators

• Optional Dispensing Heads

 

 

 

 

 

 

 

 

NOTE: This equipment is intended for the storage and display of non-potentially-hazardous bottled or canned products only.

Form No. Z2283 Rev. 06.14.10

End View

TopView

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

2

Page 2
Image 2
Perlick DC72S Installation and Operating Instructions, Sizes and Specifications, Concessionaire Dispensers, Model Nos