Be sure that the fuel source designated on your grill head is the same as that of the support system.
DO NOT USE A GRILL HEAD EQUIPPED FOR NATURAL GAS WITH LP GAS OR THE OPPOSITE.Maximum inlet pressure from System LP cannot exceed 11" W.C. The proper orifices and valving for each gas is contained in the grill head. Maximum pressure for Natural Gas is 7" W.C.
3.VERIFY ALL PARTS. IF YOU ARE MISSING ANY PARTS, PLEASE CONTACT YOUR PGS DEALER.
4.REMOVE PROTECTIVE FILM FROM ALL STAINLESS STEEL COMPONENTS (Be careful not to scratch stainless steel parts).
PERMANENT POST (IN GROUND) MOUNTING
| Your PGS permanent post | |
CONTROL | is made of aluminum. | |
PANEL | Although aluminum is | |
STIFFENING | extremely resistant to | |
BRACKETS | ||
| outdoor conditions, | |
| caution should be taken to | |
protect against soil | ||
8”POST | conditions in your area. | |
| Please consult your dealer | |
| for further information. | |
STAINLESS | PLEASE NOTE: THE | |
STEELTUBING | GRILL HEAD IS NOT TO | |
ACCESS | ||
BE FASTENED TO THE | ||
DOOR | ||
3/8” FLARE | 48" POST UNTIL THE | |
POST IS CEMENTED | ||
COUPLING | ||
INTO THE GROUND. | ||
(Not Included) | ||
GAS SUPPLY | 1. A gas supply line | |
should be trenched at | ||
LINE | ||
| least 18" below the ground | |
ACCESS | surface to prevent | |
damage from digging. | ||
HOLE ON | ||
BACK OF | You must have a supply | |
POST | line regulated to 7" W.C. | |
8” DIA. HOLE | ||
and have a master shut | ||
24” DEEP | ||
| off valve. | |
CEMENT | PLEASE CHECK WITH | |
| ||
| LOCAL CODES FOR | |
| LOCAL REGULATIONS. | |
| 2. Dig a posthole 8" in | |
| diameter and two feet | |
| deep. Locate the hole so | |
|
the grill will be at least 30" away from any combustible object or surface: above, back, left or right. The
access hole is on the BACK of the post and the notches at the top are on the front of the post. Center the post in the hole and plumb it with a level. Pour cement up to the gas line access hole.
3.Run the gas supply line into the post making a 90- degree bend to reach the access door. Connect steel connector supplied with post to gas supply line.
4.Remove the grill burner from the lower grill casting by disengaging the burner from the lower casting.
5.Carefully set grill head in place. Pass three 1/4" X 20" X 3/4" bolts provided in permanent post box through grill head cast collar and then through holes in permanent post. Attach three 1/4" X 20" kep nuts. Then attach the grease cup holder at this time on rear center bolt. Securely tighten all nuts and bolts (see illustration below). Insert an empty soup can in grease cup holder to catch juices.
| POST FLANGE |
VENTURI | BOLTS |
| |
| ATTACH POST |
| GREASE CUP |
POST | HOLDER |
Grill head to permanent post assembly
REMOVE PROTECTIVE FILM FROM CONTROL PANEL, COLLAR BOX AND ROCK GRATES
6.You will note that the bolts already attached to the control panel have two nuts on each of them. Remove the plastic thread protectors and discard. Remove the top nut on each bolt and make certain lower nut is securely tightened against control panel.
7.Attach gas line from permanent post to valve
assembly. BE CERTAIN NOT TO CROSS THREAD.
8.Insert 3/4" bolts