Be sure that the fuel source designated on your grill head is the same as that of the support system.

DO NOT USE A GRILL HEAD EQUIPPED FOR NATURAL GAS WITH LP GAS OR THE OPPOSITE.

Maximum inlet pressure from System LP cannot exceed 11" W.C. The proper orifices and valving for each gas is contained in the grill head. Maximum pressure for Natural Gas is 7" W.C.

3.VERIFY ALL PARTS. IF YOU ARE MISSING ANY PARTS, PLEASE CONTACT YOUR PGS DEALER.

4.REMOVE PROTECTIVE FILM FROM ALL STAINLESS STEEL COMPONENTS (Be careful not to scratch stainless steel parts).

PERMANENT POST (IN GROUND) MOUNTING

 

Your PGS permanent post

CONTROL

is made of aluminum.

PANEL

Although aluminum is

STIFFENING

extremely resistant to

BRACKETS

 

outdoor conditions,

 

caution should be taken to

IN-GROUND

protect against soil

8”POST

conditions in your area.

 

Please consult your dealer

 

for further information.

STAINLESS

PLEASE NOTE: THE

STEELTUBING

GRILL HEAD IS NOT TO

ACCESS

BE FASTENED TO THE

DOOR

3/8” FLARE

48" POST UNTIL THE
POST IS CEMENTED

COUPLING

INTO THE GROUND.

(Not Included)

GAS SUPPLY

1. A gas supply line

should be trenched at

LINE

 

least 18" below the ground

ACCESS

surface to prevent

damage from digging.

HOLE ON

BACK OF

You must have a supply

POST

line regulated to 7" W.C.

8” DIA. HOLE

and have a master shut

24” DEEP

 

off valve.

CEMENT

PLEASE CHECK WITH

 

 

LOCAL CODES FOR

 

LOCAL REGULATIONS.

 

2. Dig a posthole 8" in

 

diameter and two feet

 

deep. Locate the hole so

 

the grill will be at least 30" away from any combustible object or surface: above, back, left or right. The

access hole is on the BACK of the post and the notches at the top are on the front of the post. Center the post in the hole and plumb it with a level. Pour cement up to the gas line access hole.

3.Run the gas supply line into the post making a 90- degree bend to reach the access door. Connect steel connector supplied with post to gas supply line.

4.Remove the grill burner from the lower grill casting by disengaging the burner from the lower casting.

5.Carefully set grill head in place. Pass three 1/4" X 20" X 3/4" bolts provided in permanent post box through grill head cast collar and then through holes in permanent post. Attach three 1/4" X 20" kep nuts. Then attach the grease cup holder at this time on rear center bolt. Securely tighten all nuts and bolts (see illustration below). Insert an empty soup can in grease cup holder to catch juices.

K-30 BURNER

 

POST FLANGE

VENTURI

BOLTS

 

 

ATTACH POST

 

GREASE CUP

POST

HOLDER

Grill head to permanent post assembly

REMOVE PROTECTIVE FILM FROM CONTROL PANEL, COLLAR BOX AND ROCK GRATES

6.You will note that the bolts already attached to the control panel have two nuts on each of them. Remove the plastic thread protectors and discard. Remove the top nut on each bolt and make certain lower nut is securely tightened against control panel.

7.Attach gas line from permanent post to valve

assembly. BE CERTAIN NOT TO CROSS THREAD. Hand-tighten only at this time.

8.Insert 3/4" bolts (Pre-assembled on control panel) through grill head, attach nuts and securely tighten. Tighten gas line to valve assembly.

14