Figure 15 LP Hose/Regulator Connection

Figure 16 Natural Gas Hose Connection

2.TURN YOUR GAS SUPPLY (LP OR NAT) ON AND TEST ALL FITTINGS FOR

LEAKS. BEFORE ATTEMPTING TO LIGHT GRILL, BE CERTAIN BOTH VALVES ARE IN THE OFF POSITION. TURN GAS SUPPLY ON (leaving both control knobs in the "OFF" position) AND CHECK ALL CONNECTIONS WITH A SOLUTION OF 50% LIQUID SOAP, 50% WATER. SOLUTION CAN BE SPRAYED ON WITH A SPRAY BOTTLE (see Fig. 17) OR PAINTED ON ALL CONNECTIONS WITH A BRUSH. IF BUBBLES APPEAR, TURN OFF GAS, TIGHTEN FITTINGS AND TRY AGAIN. NEVER CHECK FOR LEAKS WITH A MATCH OR FLAME.

Figure 17 Leak Checking the Valve Connection

4.If no gas leaks appear (bubbles), turn off gas supply and continue assembly. IF YOU ARE UNABLE TO STOP A LEAK, CONTACT YOUR LOCAL DEALER FOR ASSISTANCE BEFORE PROCEEDING.

5.If there are no gas leaks, attach the collar box with AGA/CGA rating sticker attaching to the pedestal as follows (see Fig. 18):

Remove two #8 x 1/2" screws from bottom of control panel leaving attached Tinnerman clips.

Attach two Tinnerman clips (found in pedestal parts bag) to lower two holes in the collar box.

Place collar box inside opening in pedestal.

Insert two #8 x 1/2" screws (found in pedestal parts bag) though pedestal into collar box and Tinnerman clips.

Insert two #8 x ½" screws removed from control

panel back into control panel going first through top of collar box.

Figure 18 Collar box installation to pedestal and control panel

19