1.4 Power

Temperature: Observe the unit’s ambient temperature specifications when choosing a location for the unit. Extremes of heat or cold beyond the specified operating temperature limits may cause the unit to fail. Do not install this unit on top of other hot equipment.

Moisture: Do not expose the unit to rain or moisture. Moisture can damage internal components. Do not install this unit near sources of water.

RS485 Limitations: Total length of the RS-485 network is limited to 3000’.

1.4 Power

The ProBridge is furnished with a power supply (110 or 240 VAC). Do not use any other power supply with this product. The manufacturer accepts no responsibility for damage caused by the use of any other power supply.

Make sure installation is complete and all connections are made before applying power to the unit.

4310-0007 120VAC Power Supply

Power Supply Input

Voltage: 120 Volt AC

Tolerance: ±10%

Frequency: 60 Hz

Power Supply Output

Voltage: 12 Volt DC

Current: 110mA

Power: 1.3 Watts

Connector: 2.1mm female barrel. Center Positive

4310-0008 220VAC Power Supply

Power Supply Input

Voltage: 220 Volt AC

Tolerance: ±10%

Frequency: 50 Hz

Power Supply Output

Voltage: 12 Volt DC

Current: 110mA

Power: 1.3 Watts

Connector: 2.1mm female barrel. Center Positive