Image 6
1.5 Installation Steps Summary

1.5 Installation Steps Summary

Carefully and completely read the manuals for each piece of equipment before attempting to install and connect this equipment.

Before you start connecting other optional accessory equipment to your system, make sure that all, power, video, VCR, and monitor connections are completed, and everything is working correctly.

Wire the telemetry equipment according to that unit’s installation instruction. Use the internal diagnostic testing capabilities of the telemetry receiver to verify that the power and connections to the lens and motors are correct, and function properly.

Using the Diagram on the following page, connect the equipment in the following order:

1.Connect the CBR-PB2-PHILIPS to the Kalatel unit (DVMRe Simplex, DVMRe Triplex, DVMRe Matrix) via RS-485 port using the RJ45 to RJ45 cable. The maximum total distance allowed on the RS-485 data line (without signal amplification or modems) is 3,000 feet (1,000 meters). A 100-ohm terminator is required at each end of the RS-485 line.

2.Connect the CBR-KB3 or KTD-405 keypad to the Kalatel unit (DVMRe Simplex, DVMRe Triplex, DVMRe Matrix) via RS-485 port using the RJ45 to RJ45 cable.

3.Supply power to the Kalatel unit first and the CBR-PB2-PHILIPS second using the supplied AC to 12 VDC adapter. Via the Setup Menus for the Kalatel unit set the RS-485 network address to the appropriate number (see the Appendix for RS-485 addressing).

4.Using the provided cable, connect from the ProBridge RCVR/DRVR port to the Philips Data Converter Unit (LTC 8780). See the Philips Data Converter Unit’s (LTC 8780) installation manual for information on connecting the LTC 8780 to the AutoDome.

5.Set the ID addresses for the Philips Dome according to the table later in this manual.

6.Via a networked connected PC with WaveReader software, connect to the DVMRe unit and confirm proper control and operation of the PTZ unit.

Manual backgroundManual backgroundNOTE Manual backgroundManual background

Please note, that whenever the ProBridge is used with a KTD-405 the KB3 PTZ Protocol option in the KTD-405 menu must be set to YES. See Supervisor Programming in the KTD-405 manual.

Philips ProBridge