1.6 Connection Diagrams

This drawing depicts one Philips AutoDome connected via an RS485/422 network to a Kalatel DVMReTriplex unit, that provides remote PTZ control over Ethernet via WaveReader software, and a CBR-KB3 or KTD-405 keypad.

Philips AutoDome

DB9-F

LTC 8780

Data Converter Unit

Philips

ProBridge

4310-0047B Cable

RJ45

RJ45

#

 

 

 

AL

 

 

 

T

1

2

3

4

MUX/DVMR RCVR/DVR

5

6

7

8

 

 

 

 

 

9

10

1 1

12

 

 

 

 

 

1 3

14

1 5

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

C

D

E

 

{ F}

 

 

RJ45

KB3/KTD-405

4310-0034B Cable

4310-0034B Cable

RJ45

DVMRe Triplex

RJ45

 

Philips ProBridge