28ENGLISH

Cleaning the Shaving Unit in the Jet Clean System (1280XCC and 1250XCC)

CAUTION: Keep cleaning solution out of reach of children. Do not take internally. Avoid contact with eyes. In case of eye contact, thoroughly flush with cold water. If irritation persists, get medical attention.

Important

Only use this razor, charging stand, Jet Clean System and HQ200 cleaning solution provided to charge or clean razor.

Other Philips Norelco razors DO NOT work with this Jet Clean System.

Empty the cleaning solution canister and thoroughly rinse the canister clean with warm water every 2 weeks.

The Jet Clean System thoroughly cleans but does not disinfect your razor, therefore, do not share razor with others.

The charging plug converts 100-240V AC to less than 24V DC.

Place the Jet Clean System on a flat, stable and fluid-resistant surface to avoid any leakage. Be careful not to tip or move the Jet Clean System if it is filled with the cleaning solution.

To avoid evaporation, do not expose cleaning solution to direct sunlight.

Remove the protective razor head cap from the razor before charging or cleaning the razor in the Jet Clean System.

ENGLISH 29

Use this appliance for its intended household use as described in this manual.

1Place the Jet Clean System on a flat, level surface.

C 2 Simultaneously press the buttons located on both sides of the Jet Clean System (1) and lift the appliance off the Jet Clean canister (2).

Always remove appliance from canister by lifting straight up. Do not tilt Jet Clean System.

3Unscrew the lid on the Jet Clean Solution bottle (Model HQ200) provided with the razor. Remove the airtight seal by lifting up the tabs on the seal.

C4 Pour the Jet Clean Solution into the canister

up to a level between the two lines located inside the canister.

NOTE: ONLY USE PHILIPS NORELCO JET

CLEAN SOLUTION (MODEL HQ200) WITH

THE JET CLEAN SYSTEM. ANY OTHER

SOLUTION MAY CAUSE DAMAGE TO YOUR

RAZOR.

C When the cleaning solution level drops below the minimum level, the ‘cleaning chamber empty’ symbol will blink and the razor holder will move to the starting position.

Page 15
Image 15
Philips 1260X, 1280XCC, 1250XCC manual Place the Jet Clean System on a flat, level surface